A security engineer is configuring AWS Config for an AWS account that uses a new IAM entity. When the security engineer tries to configure AWS Config rules and automatic remediation options, errors occur. In the AWS CloudTrail logs, the security engineer sees the following error message: “Insufficient delivery policy to s3 bucket: DOC-EXAMPLE-BUCKET, unable to write to bucket, provided s3 key prefix is ‘null’.”Which combination of steps should the security engineer take to remediate this issue? (Choose two.)
Answer(s): A,B
A company is undergoing a layer 3 and layer 4 DDoS attack on its web servers running on AWS.Which combination of AWS services and features will provide protection in this scenario? (Choose three.)
Answer(s): A,D,E
A company wants to implement host-based security for Amazon EC2 instances and containers in Amazon Elastic Container Registry (Amazon ECR). The company has deployed AWS Systems Manager Agent (SSM Agent) on the EC2 instances. All the company's AWS accounts are in one organization in AWS Organizations. The company will analyze the workloads for software vulnerabilities and unintended network exposure. The company will push any findings to AWS Security Hub, which the company has configured for the organization.The company must deploy the solution to all member accounts, including new accounts, automatically. When new workloads come online, the solution must scan the workloads.Which solution will meet these requirements?
Answer(s): C
A company uses AWS Organizations to manage several AWS accounts. The company processes a large volume of sensitive data. The company uses a serverless approach to microservices. The company stores all the data in either Amazon S3 or Amazon DynamoDB. The company reads the data by using either AWS Lambda functions or container-based services that the company hosts on Amazon Elastic Kubernetes Service (Amazon EKS) on AWS Fargate.The company must implement a solution to encrypt all the data at rest and enforce least privilege data access controls. The company creates an AWS Key Management Service (AWS KMS) customer managed key.What should the company do next to meet these requirements?
An AWS Lambda function was misused to alter data, and a security engineer must identify who invoked the function and what output was produced. The engineer cannot find any logs created by the Lambda function in Amazon CloudWatch Logs.Which of the following explains why the logs are not available?
Answer(s): A
Post your Comments and Discuss Amazon SCS-C02 exam prep with other Community members:
Our website is free, but we have to fight against AI bots and content theft. We're sorry for the inconvenience caused by these security measures. You can access the rest of the SCS-C02 content, but please register or login to continue.