What is the MINIMUM cover for underground conduit?

  1. 152 mm (6 in)
  2. 305 mm (12 in)
  3. 457 mm (18 in)
  4. 610 mm (24 in)
  5. 762 mm (30 in)

Answer(s): D



When installing underground entrances, no more than ________ 90-degree bends should be included between pulling points.

  1. One
  2. Two
  3. Three
  4. Four

Answer(s): B



You are placing an entrance cable between two buildings connected by a conduit 205.3 m (588 ft) in length.
What would be the MAXIMUM length of unlisted OSP cable that could be used before you terminate the cable or transition it to a listed cable?

  1. 185 m (607 ft)
  2. 200 m (656 ft)
  3. 209 m (686 ft)
  4. 213 m (700 ft)
  5. 216 m (708 ft)

Answer(s): C



Buildings larger than ________ must contain a dedicated room for the termination of entrance facilities.

  1. 5529 square m (60,000 square ft)
  2. 7389 square m (80,000 square ft)
  3. 9300 square m (100,000 square ft)
  4. 11,160 square m (120,000 square ft)
  5. 13,300 square m (140,000 square ft)

Answer(s): C



The MOST common medium used to provide service to the access point (AP) is ________ cable.

  1. Singlemode optical fiber
  2. Multimode optical fiber
  3. Unbalanced twisted pair
  4. Balanced twisted pair

Answer(s): D