Blue Prism AD01 Exam
Blue Prism Accredited Developer (Page 10 )

Updated On: 9-Feb-2026

If you change a session variable when will the new value be available to the process?

  1. Immediately
  2. Next time a new case is taken from a WQ
  3. Next time resource PC starts
  4. Next time the process starts

Answer(s): A

Explanation:

Reason: It updates the values immediately.



When a process is running in Control Room which of the following functions within the process can be accessed from Control Room to request the process to stop?

  1. Stop()
  2. IsStopRequestec?
  3. IsStopRequested()
  4. StopNow()
  5. Stop?
  6. StopNow?

Answer(s): C

Explanation:

Reason: IsStopRequested() function is used for the immediate stop provided by the blueprism (mentioned in the foundation course)



An action called Get Account details' fails with the following exception detail:



Which of the following could cause this exception?

  1. An internal error always indicates a problem with the Blue Prism product. The Blue Prism support team should be contacted for assistance
  2. The Read Details action is not connected to another stage so cannot execute.
  3. The Business Object has not been coupled to the application by either launching it or attaching to it.
  4. The Read Details action in the Get Account Details Business Object no longer exists but the Process is attempting to use it.

Answer(s): C

Explanation:

Reason: This is happening when the application is not attached or launched and user tries to read the action. Exercise also mentioned in the foundation course. Below snapshot is from the Exception pdf.



Consider the following process flow:



What is the problem with this flow?

  1. There is nothing wrong with this flow.
  2. The exception handling in this flow can be removed because an Attach action in a navigate stage should always work if configured correctly
  3. The Attach Block should be enlarged to also include the Waited Long Enough decision stage.
  4. The flow contains a recover stage and a route from it without a resume stage. This will cause internal errors on future exceptions thrown in the same session.
  5. The 0.5 second wait stage should be removed so that the retries can be performed at full speed.

Answer(s): A



Study the following process flow on the Main Page of a process where the intention is to preserve the current exception.



What is wrong with the design?

  1. The exception handling is not within an Exception Block.
  2. The exception caught by Recover2 will not be preserved by the Re-Throw Exception stage
  3. The Send Alerts process will never be run
  4. Because the flow is on the Main Page of the process there should not be a `Re-Throw' Exception stage as there are no parent/calling pages for the exception to bubble up' to.

Answer(s): B

Explanation:

Reason: After resume stage the exception is dead so the Re thrown will not worked.






Post your Comments and Discuss Blue Prism AD01 exam prep with other Community members:

Join the AD01 Discussion