Please refer to the exhibit.


A Developer is unable to pass Collection data as an Input Parameter because the Collection is not visible under available Data Items.
What is the reason for this issue?

  1. There are more than four fields in the Collection
  2. The Collection fields are not defined
  3. There is a block surrounding the Collection
  4. The referenced Collection is not set to global

Answer(s): D

Explanation:

In Blue Prism, for a Collection (or any Data Item) to be accessible across pages or in Action stage input parameters, it must be set to Global. Since the Collection is not visible under available Data Items, the issue is that it is not marked as global.



Which ONE of the following Stages can only be found in the Process Studio?





Answer(s): A

Explanation:

Chosen option represents the Page stage, which is only available in Process Studio. It allows navigation to sub-
pages within a process, a feature not present in Object Studio.



Please, refer to the exhibits.








The Output Data Item is a Text data type.
What will be the outcome when the Developer clicks Go in Process Studio?

  1. A System Exception will be thrown
  2. Data Item Output = A
  3. Data Item Output = B
  4. An Internal Exception will be thrown

Answer(s): B

Explanation:

The input value is "Blue Prism!", which has a length of 11, so it does not satisfy Path A (Len([Input])
= 10).
It does satisfy Path B (Right([Input], 6) = "Prism!"), so it takes Path B, and the expression in Answer B sets Output = B.



Please refer to the exhibits.










This is a detail of a Process sub-page.
SignUpDate, CurrentDate, and ExpiryDate Data Items are of the ‘Date’ data type.
Status and Output Data Items are of the ‘Text’ data type.
What is the output of this logic when the page is executed till its End stage?

  1. Subscription Status = Active; Expiration Date = 04-07-2023
  2. Subscription Status = Expired; Expiration Date = 04-07-2023
  3. Internal Error at the Decision stage as > function cannot be used for dates
  4. Internal Error at the Calc3 stage as a date cannot be stored in a Text Data Item

Answer(s): A

Explanation:

The current date (13-06-2023) is earlier than the expiry date (04-07-2023), so the condition [Current Date]
> [Expiry Date] evaluates to False. The "No" path is followed, setting Status = "Active", and the final output becomes:
Subscription Status = Active; Expiration Date = 04-07-2023.



Please refer to the exhibits.










How many Full Time Employees will the generated Report include?

  1. 0
  2. 2
  3. 1
  4. 4

Answer(s): A

Explanation:

The Decision stage is checking if [Data.Status] = "FT" (abbreviation for Full Time), but the actual data contains the full text "Full Time". Since no value matches "FT", all rows will be evaluated as not full-time and removed from the collection. Therefore, the generated report will include 0 Full Time Employees.