Free 350-601 Exam Braindumps (page: 53)

Page 52 of 125

An engineer is performing a configuration on a Cisco Nexus 5000 Series Switch. The requirement is for the current Fibre Channel IDs in VSAN 120 to be saved across reboots. The Cisco environment also must integrate with a third-party solution that requires persistent Fibre Channel IDs for the VSAN. The WWN of the Cisco switch must be 33:e8:00:05:30:00:16:df and its Fibre Channel ID 0x070128. Which command set meets these requirements?

  1. fcdomain fcid database
    vsan 120 wwn 33:e8:00:05:30:00:16:df fcid 0x070128
    fcdomain fcid persistent vsan 120
  2. fabric-binding database vsan 120
    vsan 120 wwn 33:e8:00:05:30:00:16:df fcid 0x070128
  3. vsan 120 wwn 33:e8:00:05:30:00:16:df fcid 0x070128
    fabric-binding activate vsan 120
    purge fcdomain fcid vsan 4
  4. ysan 120 wwn 33:e8:00:05:30:00:16:df fcid 0x070128
    fcdomain fcid preserve vsan 120

Answer(s): A


Reference:

https://www.cisco.com/en/US/docs/storage/san_switches/mds9000/sw/rel_1_x/1_0_2a/san-os/configuration/guide/Domains.pdf



Refer to the exhibit.


An engineer must configure FCoE between the N9K-A switch and the FCF-A Nexus 9000 core switch. The deployment has these characteristics:

-The N9K-A and N9K-B top-of-rack switches share the domain ID of the core switches.
-The hosts are equipped with converged network adapters.
-The only VSAN that is used is permitted to traverse port-channel 100 is VSAN 20.

Which configuration completes the FCoE configuration on the N9K-A device?

  1. N9K-A(config)# feature-set fcoe-npv
    N9K-A(config)# interface vfc-port-channel 100
    N9K-A(config-if)# switchport mode E
    N9K-A(config-if)# switchport trunk allowed vsan 1, 20
  2. N9K-A(config)# feature-set fcoe-npv
    N9K-A(config)# interface vfc-port-channel 100
    N9K-A(config-if)# switchport mode NP
    N9K-A(config-if)# switchport trunk allowed vsan 20
  3. N9K-A(config)# feature fcoe
    N9K-A(config)# feature npv
    N9K-A(config)# interface vfc 100
    N9K-A(config-if)# bind interface port-channel 100
    N9K-A(config-if)# switchport mode N
    N9K-A(config-if)# switchport trunk allowed vsan 1, 20
  4. N9K-A(config)# feature fcoe
    N9K-A(config)# feature npv
    N9K-A(config)# interface vfc 100
    N9K-A(config-if)# bind interface port-channel 100
    N9K-A(config-if)# switchport mode F
    N9K-A(config-if)# switchport trunk allowed vsan 20

Answer(s): B



A customer has a requirement for an automation solution that supports periodically acquiring configuration from a centralized server and aligning UCS servers to their desired state.
Which open-source tool meets this requirement?

  1. SaltStack
  2. Kubernetes
  3. Puppet
  4. Terraform

Answer(s): C



An administrator needs to configure an automated policy to shut down a link when a given threshold is exceeded on MDS switch. Which feature needs to be used?

  1. RMON
  2. EEM
  3. Call Home
  4. Scheduler

Answer(s): B






Post your Comments and Discuss Cisco® 350-601 exam with other Community members:

350-601 Discussions & Posts