Free 350-601 Exam Braindumps (page: 58)

Page 57 of 125

The Cisco Nexus switch Generic Online Diagnostics policy for a PortLoopback test requires 10 consecutive failures to error disable the port. The customer wants to change it to 5 consecutive failures. Which configuration applies the changes for module 1 only?

  1. Nexus(config)# event manager applet custom-PortLoopback override PortLoopback
    Nexus(config-applet)# event gold mod all test PortLoopback testing-type bootup consecutive-
    failure 5
    Nexus(config-applet)# action 1 publish-event
  2. Nexus(config)# event manager applet custom-PortLoopback override PortLoopback Nexus(config-applet)# event gold mod 1 test PortLoopback testing-type bootup consecutive-failure 5
    Nexus(config-applet)# action 1 publish-event
  3. Nexus(config)# event manager applet custom-PortLoopback override PortLoopback
    Nexus(config-applet)# event gold mod all test PortLoopback testing-type monitoring consecutive-
    failure 5
    Nexus(config-applet)# action 1 policy-default
  4. Nexus(config)# event manager applet custom-PortLoopback override PortLoopback
    Nexus(config-applet)# event gold mod 1 test PortLoopback testing-type monitoring consecutive-
    failure 5
    Nexus(config-applet)# action 1 policy-default

Answer(s): D


Reference:

https://www.ciscolive.com/c/dam/r/ciscolive/us/docs/2017/pdf/BRKDCN-3234.pdf



Refer to the exhibit.


Which command needs to be added to the line starting with the “file” keyword to have the generated running-config file with the name ‘fusion-config_’ and current date?

  1. str.(‘fusion-config_’) + date
  2. (‘fusion-config_’) + date
  3. (‘fusion-config_ + date’)
  4. string((‘fusion-config_’) + date

Answer(s): A



A network engineer must create an EEM script that saves a copy of the running configuration on bootflash and writes a message to syslog when a user saves the configuration to a Cisco Nexus Series switch. Which configuration set should be applied to complete this task?





Answer(s): B


Reference:

https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/7-x/system_management/ configuration/guide/b_Cisco_Nexus_9000_Series_NX-OS_System_Management_Configuration_Guide_7x/ b_Cisco_Nexus_9000_Series_NX-OS_System_Management_Configuration_Guide_7x_chapter_01110.html



DRAG DROP (Drag and Drop is not supported)
An engineer must shut down the Ethernet 1/2 interface when the Ethernet 4/5 interface state is down. Drag and drop the CLI commands from the bottom onto the blanks in the exhibit to implement this EEM. Not all commands are used.
Select and Place:

  1. See Explanation section for answer.

Answer(s): A

Explanation:






Post your Comments and Discuss Cisco® 350-601 exam with other Community members:

350-601 Exam Discussions & Posts