Free SK0-005 Exam Braindumps
CompTIA Server+ Certification Questions 251–255 (page: 52)

Updated On: 10-Feb-2026

An administrator has been asked to increase the storage capacity of a stand-alone file server, but no further expansion slots are available.
Which of the following would be the FASTEST solution to implement with no downtime?

  1. Configure a RAID array.
  2. Replace the current drives with higher-capacity disks.
  3. Implement FCoE for more storage capacity.
  4. Connect the server to a SAN.

Answer(s): D



A Linux server was recently updated. Now, the server stops during the boot process with a blank screen and an fs> prompt.
Which of the following is the MOST likely cause of this issue?

  1. The system is booting to a USB flash drive.
  2. The UEFI boot was interrupted by a missing Linux boot file.
  3. The BIOS could not find a bootable hard disk.
  4. The BIOS firmware needs to be upgraded.

Answer(s): B



A server technician arrives at a data center to troubleshoot a physical server that is not responding to remote management software. The technician discovers the servers in the data center are not connected to a KVM switch, and their out-of-band management cards have not been configured.
Which of the following should the technician do to access the server for troubleshooting purposes?

  1. Connect the diagnostic card to the PCIe connector.
  2. Connect a console cable to the server NIC.
  3. Connect to the server from a crash cart.
  4. Connect the virtual administration console.

Answer(s): C



Which of the following describes a configuration in which both nodes of a redundant system respond to service requests whenever possible?

  1. Active-passive
  2. Failover
  3. Active-active
  4. Failback

Answer(s): C



Users have noticed a server is performing below baseline expectations.
While diagnosing the server, an administrator discovers disk drive performance has degraded. The administrator checks the diagnostics on the RAID controller and sees the battery on the controller has gone bad.
Which of the following is causing the poor performance on the RAID array?

  1. The controller has disabled the write cache.
  2. The controller cannot use all the available channels.
  3. The drive array is corrupt.
  4. The controller has lost its configuration.

Answer(s): A