Refer to the Exhibit.



You are testing failover from a host perspective. The host has been configured in a "Failover Only MPIO" configuration.
When running IOmeter if the Data Path 2 cable from the host is disconnected, will the host survive the failover?

  1. No; Failover MPIO is configured for only Data Path 1
  2. No; IOmeter is sending I/O only on one path
  3. Yes; the server has Data Path 1 connected to both controllers
  4. Yes; Failover MPIO should failover

Answer(s): D



A file server using an SC7020 storage array was impacted by ransomware in the morning and a majority of the files need to be recovered. The backup from the previous night did not run. Is there anything that can be done on the SC7020 array to help recover these files?

  1. Yes, if there is a snapshot from before the ransomware on the volume(s) were impacted.
    Volume(s) can be rolled back to this snapshot.
  2. Nothing can be done on the SC7020 to assist with this recovery.
  3. Yes, if there is a snapshot from before the ransomware on the volume(s) were impacted. A Replay can be created from this snapshot and the files recovered.
  4. Yes, if there is a snapshot from before the ransomware on the volume(s) were impacted. A View volume can be created from this snapshot and the files recovered.

Answer(s): A



Which best practices should be followed when using iSCSI to connect SC Series arrays and hosts?

  1. Use dedicated switches for iSCSI.Two separate VLANS for multipathed iSCSI using separate IP subnets.Gigabit full duplex between Storage Center and all local servers.
  2. Use separate IP subnets for multipathed iSCSI separated by VLANS when using the same switch.Gigabit full duplex between Storage Center and all local servers
  3. Use separate switches for iSCSI.Two separate VLANs for multipathed iSCSI using separate IP subnets.Unicast and multicast storm control enabled on all iSCSI switches.
  4. Use separate VLANs for multipathed iSCSI using separate IP subnets when using the same switch.Bi-directional flow control disabled between Storage Center and servers.

Answer(s): D



You are implementing a front-end connection in Legacy Port Mode on an SC4020 16 Gb FC array with two FC switches. Can full redundancy be achieved and if so, how many ports per switch can be used by the SC Series array?

  1. No; full redundancy cannot be achieved
  2. Yes; two ports on each of the FC switches
  3. Yes; four ports on each of the FC switches
  4. Yes; eight ports on each of the FC switches

Answer(s): B



A customer wants to have the SED feature enabled through Dell Storage Manager (DSM) 2016 R2.
How is encryption enabled on the SED?

  1. SED feature must be licensed.
  2. External KMS is required and must be activated during installation of the array.
  3. SED feature uses a dedicated ASIC in each controller and can be enabled at any time.
  4. SED encrypts data by default.

Answer(s): A