Which type of Humidifier suspends quartz lamps over an open pool of water?
Answer(s): A
Infrared humidifiers are a type of humidifier that use quartz lamps to heat water in an open pool and evaporate it into the air. They are energy-intensive and require frequent maintenance and cleaning. They are not recommended for data centers, as they can introduce contaminants and bacteria into the air, and increase the risk of fire and electrical hazards.
EPI Data Centre Training Framework, CDCP Preparation Guide, Make Humidification Adjustments | ENERGY STAR
Which one of the following is a core objective of a Business Value in an organization?
Answer(s): D
According to the EPI Data Centre Professional (CDCP®) Reference Materials, a core objective of a Business Value in an organization is to create value for customers and stakeholders1. This means delivering products or services that meet or exceed customer expectations, while also generating profits or benefits for the organization and its shareholders. Reducing costs, reducing the deficit, and increasing sales are possible ways to achieve this objective, but they are not the core objective itself.
1: EPI Data Centre Professional (CDCP®) Reference Materials, page 9.
systems are designed specifically to protect the structure of a building.
Answer(s): C
Water sprinkler systems are designed to protect the structure of a building from fire by suppressing or extinguishing the flames with water. Water sprinkler systems are typically installed in the ceiling or walls of a building and are activated by heat or smoke detectors. Water sprinkler systems can reduce the risk of fire spreading and causing structural damage to the building.
· EPI Data Centre Professional (CDCP®) Preparation Guide, page 28 · Fire Protection Systems for Data Centers | EPI
Which Class of Fires involves ordinary combustible materials such as paper, wood and cloth?
According to the CDCP® Preparation Guide, Class A fires involve ordinary combustible materials such as paper, wood and cloth. These materials leave behind ash or embers when they burn. Class A fires can be extinguished by water or other cooling agents that reduce the temperature of the fuel below its ignition point.
CDCP® Preparation Guide, page 30. Basics of Fire Protection in a Data Center. 3 Levels of Data Center Fire Protection Standards. Three Levels of Data Center Fire Protection.