An LTM device supports two power supplies. The value of the BigDB key "platform.powersupplymonitor" is equal to enable.Where would the error message be visible if one of the power supplies fails or is NOT plugged in?
Answer(s): B
An LTM Specialist loads a UCS file generated on a different LTM device and receives the following error message:"mcpd[2395]: 01070608:0: License is not operational (expired or digital signature does not match contents)"Which command should the LTM Specialist use to prevent the error?
Answer(s): E
These log entries can have different root causes:Jun 28 05:01:21 LTM_A notice mcpd[27545]: 0107143a:5: CMI reconnect timer: enabledJun 28 05:01:21 LTM_A notice mcpd[27545]: 01071431:5: Attempting to connect to CMI peer 1.1.1.2 port 6699Jun 28 05:01:21 LTM_A notice mcpd[27545]: 01071432:5: CMI peer connection established to 1.1.1.2 port 6699Jun 28 05:01:26 LTM_A notice mcpd[27545]: 0107143a:5: CMI reconnect timer: disabled, all peers are connectedWhich two commands should be used to obtain additional information on these entries? (Choose two.)
Answer(s): B,C
An LTM Specialist wants to allow access to the Always On Management (AOM) from the network.Which two methods should the LTM Specialist use to configure the AOM interface? (Choose two.)
Answer(s): B,D
An LTM Specialist troubleshooting an issue looks at the following /var/log/ltm entries:Oct 2 04:52:42 slot1/tmm7 crit tmm7[21734]: 01010201:2: Inet port exhaustion on 10.143.109.5 to 10.143.147.150:53 (proto 17)Oct 2 05:37:16 slot1/tmm7 crit tmm7[21734]: 01010201:2: Inet port exhaustion on 10.143.109.5 to 10.143.147.150:53 (proto 17)Oct 2 05:57:32 slot1/tmm2 crit tmm2[21729]: 01010201:2: Inet port exhaustion on 10.143.109.5 to 10.143.147.150:53 (proto 17)Oct 2 06:30:03 slot1/tmm7 crit tmm7[21734]: 01010201:2: Inet port exhaustion on 10.143.109.5 to 10.143.147.150:53 (proto 17)Oct 2 06:37:44 slot1/tmm2 crit tmm2[21729]: 01010201:2: Inet port exhaustion on 10.143.109.5 to 10.143.147.150:53 (proto 17)Oct 2 06:47:05 slot1/tmm5 crit tmm5[21732]: 01010201:2: Inet port exhaustion on 10.143.109.5 to 10.143.147.150:53 (proto 17)Which configuration item should the LTM Specialist review to fix the issue?
Answer(s): A
Post your Comments and Discuss F5 301b exam prep with other Community members:
Our website is free, but we have to fight against AI bots and content theft. We're sorry for the inconvenience caused by these security measures. You can access the rest of the 301b content, but please register or login to continue.