Free HPE0-S22 Exam Braindumps (page: 7)

Page 6 of 16

A customer operates a data center based on third-party servers, which includes third-party storage with an iSCSI SAN.
The architect needs to design a solution that can seamlessly access the current data from a new HPE Moonshot system.
How can the HPE Moonshot system access the legacy storage?

  1. using native iSCSI target software to connect to the storage on a dedicated LAN
  2. using native iSCSI initiator to connect to the storage on a dedicated LAN
  3. using native iSCSI initiator to connect to the storage on the management LAN
  4. using an HPE Multifunction router to convert iSCSI to Virtual Connect

Answer(s): B



What defines lease rate factor (LRF)?

  1. the sum of all costs incurred
  2. the periodic rental payment, expressed as a percentage of equipment cost
  3. the cost of the direct capital expenditure, divided by the expected lifespan of the equipment
  4. the expected time to recover the initial investment

Answer(s): B



View the Exhibit.

Refer to the exhibit. A customer has an HPE c7000 enclosure managed by HPE OneView with HP BL460c Gen9 servers in a vSphere cluster. The customer has multiple vLANs trunked from the top of rack (TOR) switches to the Virtual Connect modules in the enclosure. Due to network Access Control List (ACL) requirement and guidelines from the networking department, all network traffic should be forced to an upstream switch using the
Virtual Connect Private Network feature.
The customer reports slow network response.
Which modification can the architect recommend to improve network performance?

  1. Change the FlexFabric 20/40 adapter modules with Flex 10/100 modules.
  2. Change the FlexFabric adapter modules with Flex-10 adapter modules.
  3. Remove the Management network from the uplinks.
  4. Put the vMotion network in a separate uplink set and disable “Private Network”.

Answer(s): A



A customer is considering upgrading from a BL460c Gen8 to a BL460c Gen9 server. The customer needs to retain the ESXI V5.5 boot volumes and enable UEFI secure boot mode on the new BL460c Gen 9 server.
What should the architect explain to the customer?

  1. The ESXI V5.5 volume will not boot in UEFI mode.
  2. The server must be configured to support GPT boot drives.
  3. ESXI V5.5 needs to be patched up to ESXI V6.
  4. Secure boot mode must be enabled and certificate installed.

Answer(s): C






Post your Comments and Discuss HP HPE0-S22 exam with other Community members:

HPE0-S22 Discussions & Posts