Free H13-624_V5.5 Exam Braindumps
HCIP-Storage V5.5 Questions 16–20 (page: 5)

Updated On: 10-Feb-2026

When delivering a flash storage project, Huawei engineers introduced the arbitration mechanism of HyperMetro to the customer.
Which of the following statements is false about the arbitration modes?

  1. If no quorum server is configured, HyperMetro works in static priority mode.
    When an arbitration occurs, the preferred site wins the arbitration and provides services.
  2. In static priority mode, if the preferred site of a HyperMetro pair breaks down, the non-preferred site does not automatically take over HyperMetro services. As a result, the services stop, and the customer must forcibly start the services at the non-preferred site.
  3. In quorum server mode, the quorum server can be deployed only on physical machines and not on virtual machines.
  4. In quorum server mode, if the link between storage systems is down, each storage system sends an arbitration request to the quorum server.

Answer(s): C



An industry customer has purchased several Huawei flash storage devices for service deployment. An engineer wants to configure the HyperSnap feature on the storage devices. However, during the configuration, the engineer discovers that snapshots cannot be created for an existing protection group. The possible cause is that the storage pool where the source LUNs in the protection group reside has no available capacity.

  1. TRUE
  2. FALSE

Answer(s): A



An industry customer has purchased a Huawei OceanStor Pacific scale-out storage system for service deployment. An engineer configures NFS file sharing on the storage system through NFSv4.0.
Which of the following commands can the engineer use to switch the user view to the developer view on the command line interface (CLI)?

  1. change domain ad_manager operation=develop
  2. change dns general address=develop
  3. change user_mode current_mode user_mode=developer
  4. change nas_Idap advanced_config

Answer(s): C



An industry customer purchased several Huawei OceanStor Pacific series scale-out storage devices for service deployment, and an engineer configured the SmartMigration feature on the storage devices. Now the engineer wants to change the split mode and migration rate of a SmartMigration task due to changes in service requirements.
Which of the following SmartMigration running statuses does not allow the engineer to perform the change?

  1. Interrupted
  2. Paused
  3. Faulty
  4. Migrating

Answer(s): D



A government customer has purchased several Huawei OceanStor Pacific series storage devices. An engineer wants to install the distributed parallel client (DPC) on the storage devices. The operations before DPC installation have been completed. Now, the engineer needs to add DPC nodes.
Which of the following statements are true about adding nodes?

  1. The engineer can add nodes by batch importing nodes or manually adding nodes. In either mode, authentication is not required.
  2. If the engineer selects "Manually Add Node" on DeviceManager, the engineer must enter the management IP address of the node to be added.
  3. If the engineer selects "Manually Add Node" on DeviceManager, the engineer must enter the service IP address of the node to be added.
  4. If the engineer selects "Batch Import Node" on DeviceManager, the engineer must fill in the downloaded template, and upload the template to complete batch import.

Answer(s): B,D



Viewing page 5 of 13
Viewing questions 21 - 25 out of 375 questions


Post your Comments and Discuss Huawei H13-624_V5.5 exam prep with other Community members:

AI Tutor AI Tutor 👋 I’m here to help!