Which of the following description of the storage protocol is correct? (Multiple choice)

  1. FC InfiniBand SAS PCI-edouble can be a carrier of the SCSI protocol
  2. InfiniBand Transmission Speed "FC Transmission Speed" iSCSI transmission speed
  3. FCoE technology for GE and 10GE Ethernet
  4. FCoE SAS InfiniBand has its own switch product

Answer(s): A,D



Customers in the process of using Simpana software, CS for some reason can not start normally. You need to restore the CS. Which of the following situations will cause the restoration to fail?

  1. The backup server and the ring server can not communicate properly
  2. The link between the backup server and the media server is faulty
  3. Backup server SQL database failure
  4. DDB is abnormal

Answer(s): C



Dual-live solution: the optical fiber link between two data centers in the same city needs to be deployed with a wavelength division device.

  1. 10
  2. 25
  3. 50 D. 100

Answer(s): B



The OceanStor 18000 system used by a client business application has a total of three pools, each of which is a 9-disk RAID5. Someday analyzing the log of business interruption, we found that there are some scenarios in the system that caused the failure. What will cause the host access to the stored business in the following scenario? (Multiple choice)

  1. In the fully redundant group environment, occurred the master reset.
  2. With the BST (bad track) feature turned off, a BST bad track appears on the LUN.
  3. The POOL where the business is located is all thin LUN and not a snapshot. LUN copy, clone and copy services are configured in the log POOL, which is a space full of print information.
  4. Log in the following print:
    2014-01-19 08:04:40} {Receive a disk-fault event of the disk (328) of pool (2) from ctrl.} 2014-01-19 08:40:35} {Receive a disk-fault event of the disk (613) of pool (3) from ctrl.}

Answer(s): B,C



When the N8500 (V200R001) clustered NAS operating system is archived as a banknote imaging platform, the information about storage units and networks is set. Choose the correct statement.

  1. When the access to the N8500 is all on the intranet, and the client traffic is not equal, it is recommended to configure the "balance-alb" mode (that is, bond 6 mode).
  2. When creating a LUN, write business for a long time, the stripe depth recommended 512K
  3. If the RAID group is configured as RAID 6, the number of member disks is recommended to be 9 disks, and it is not recommended to configure the RAID group.
  4. Fencing LUN should be placed in the same RAID group.

Answer(s): A