Updated On: 9-Feb-2026

Regardless of the aggregation type or non-aggregation type OTU, the SDH signal R_LOS received by the client side is processed on the wavelength division side of the OTU board, and the REM_SF alarm is generated on the downstream client side.

  1. True
  2. False

Answer(s): A



Standard FEC, AFEC, and HFEC techniques all increase FEC overhead, and the resulting coding gain is incrementally increased.

  1. True
  2. False

Answer(s): A



For the aggregation type OTU board, when the ODUk_PM_AIS alarm is received on the WDM side of the receiving OTU board, the following describes the OTN standard signal processing, which is correct.

  1. No processing and reporting on this site
  2. Return OTUk_BDI alarm to the wavefront side of the upstream station
  3. Generate SD events on the WDM side of the B station OTU, trigger channel service switching
  4. After the alarm processing on the client side, the ODUk_PM_AIS alarm can be detected in the
    client device.

Answer(s): D



When you use the fiber synchronization mode to create a fiber, the NE does not create a fiber. The so-called "conflict fiber" does not need to be created on the NMS.

  1. True
  2. False

Answer(s): B



The monitoring channel did not participate in the amplification during the entire transmission, but was terminated and regenerated at each site.

  1. True
  2. False

Answer(s): A