Free H35-260 Exam Braindumps (page: 24)

Page 23 of 85

When the local ODUK signal is plugged into LCK, what processing will the downstream station not do?

  1. Report the ODUK_PM_LCK alarm
  2. Insert ODUK_AIS information
  3. Return ODUK_PM_BDI
  4. Insert ODUK_PM_LCK alarm

Answer(s): D



When any of the following situations occurs, the ODUk_PM_DEG alarm will be reported on the NMS?

  1. When the number of errors in the PM segment of the ODU layer exceeds the limit, the number of errors exceeds the specified error threshold.
  2. When the PM segment of the ODU layer is degraded by bit errors, and the number of error codes exceeds the specified bit error degradation threshold
  3. The ODUkTCMng signal is degraded, and the number of bit errors exceeds the specified error threshold.
  4. The error error of the ODUkTCMn layer exceeds the limit, and the number of error errors exceeds the specified error degradation threshold.

Answer(s): B



When it is found that the local end reports the ETH_LOS alarm, the fault can be located by the switch-back method. If the alarm disappears after the ODF loops back to the local end, which of the following may be the cause?

  1. The peer board or pigtail is faulty
  2. Line failure
  3. The local board or pigtail is faulty
  4. Device false positives

Answer(s): A



When the device reports the PW_APS_DEGRADED alarm, what is the problem with the LTE service carried by the station?

  1. Business interruption
  2. One of the working protection channels fails
  3. The working protection channel is invalid
  4. None of the working protection channels fail

Answer(s): B






Post your Comments and Discuss Huawei H35-260 exam with other Community members:

H35-260 Discussions & Posts