Free CCSP Exam Braindumps
Certified Cloud Security Professional (CCSP) Questions 206–210 (page: 43)

Updated On: 10-Feb-2026

You just hired an outside developer to modernize some applications with new web services and functionality. In order to implement a comprehensive test platform for validation, the developer needs a data set that resembles a production data set in both size and composition.

In order to accomplish this, what type of masking would you use?

  1. Development
  2. Replicated
  3. Static
  4. Dynamic

Answer(s): C

Explanation:

Static masking takes a data set and produces a copy of it, but with sensitive data fields masked. This allows for a full data set from production for testing purposes, but without any sensitive data. Dynamic masking works with a live system and is not used to produce a distinct copy. The terms "replicated" and "development" are not types of masking.



In order to prevent cloud customers from potentially consuming enormous amounts of resources within a cloud environment and thus having a negative impact on other customers, what concept is commonly used by a cloud provider?

  1. Limit
  2. Cap
  3. Throttle
  4. Reservation

Answer(s): A

Explanation:

A limit puts a maximum value on the amount of resources that may be consumed by either a system, a service, or a cloud customer. It is commonly used to prevent one entity from consuming enormous amounts of resources and having an operational impact on other tenants within the same cloud system. Limits can either be hard or somewhat flexible, meaning a customer can borrow from other customers while still having their actual limit preserved. A reservation is a guarantee to a cloud customer that a certain level of resources will always be available to them, regardless of what operational demands are currently placed on the cloud environment. Both cap and throttle are terms that sound similar to limit, but they are not the correct terms in this case.



Where is a DLP solution generally installed when utilized for monitoring data at rest?

  1. Network firewall
  2. Host system
  3. Application server
  4. Database server

Answer(s): B

Explanation:

To monitor data at rest appropriately, the DLP solution would be installed on the host system where the data resides. A database server, in some situations, may be an appropriate answer, but the host system is the best answer because a database server is only one example of where data could reside. An application server processes data and typically sits between the data and presentation zones, and as such, does not store data at rest. A network firewall would be more appropriate for data in transit because it is not a place where data would reside.



Which of the following aspects of security is solely the responsibility of the cloud provider?

  1. Regulatory compliance
  2. Physical security
  3. Operating system auditing
  4. Personal security of developers

Answer(s): B

Explanation:

Regardless of the particular cloud service used, physical security of hardware and facilities is always the sole responsibility of the cloud provider. The cloud provider may release information about their physical security policies and procedures to ensure any particular requirements of potential customers will meet their regulatory obligations. Personal security of developers and regulatory compliance are always the responsibility of the cloud customer. Responsibility for operating systems, and the auditing of them, will differ based on the cloud service category used.



Humidity levels for a data center are a prime concern for maintaining electrical and computing resources properly as well as ensuring that conditions are optimal for top performance.

Which of the following is the optimal humidity level, as established by ASHRAE?

  1. 20 to 40 percent relative humidity
  2. 50 to 75 percent relative humidity
  3. 40 to 60 percent relative humidity
  4. 30 to 50 percent relative humidity

Answer(s): C

Explanation:

The American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE) recommends 40 to 60 percent relatively humidity for data centers. None of these options is the recommendation from ASHRAE.



Viewing page 43 of 104
Viewing questions 211 - 215 out of 512 questions