Free Nutanix Certified Professional-Multicloud Infrastructure (NCP-MCI) 6.5 Exam Exam Braindumps (page: 9)

Page 8 of 44

An administrator is troubleshooting vDisk performance issues in a Nutanix cluster with hybrid disks.
The VMs all have Flash Mode enabled.

But users are reporting disk latency.

What could cause the performance issues?

  1. Flash mode is disabled when a node fails.
  2. Compression is disabled on the vDisk storage container.
  3. The VMs vDisks are in multiple containers.
  4. Data size for flash mode exceeds 25% of the SSD capacity.

Answer(s): D

Explanation:

data size for flash mode exceeds 25% of the SSD capacity could cause the performance issues. Flash mode is a feature that allows vDisks to be pinned to SSDs for faster access, but it has a limit of 25% of the SSD capacity per node. If this limit is exceeded, some vDisks may be evicted from flash mode and cause disk latency2.



An administrator is performing validation testing of a new-deploy cluster. During this test, the administrator disconnect each LAN interface from each of the nodes while pinging the hypervisor and guest VMs.

When the first interface is disconnected, pings continue as expected to the hypervisor, but pings stop responding from the guest. Pings continue when the interface is reconnected. When the second interface is disconnected, pings continue to both the hypervisor and guest VMs.

What could be the cause of this error?

  1. This is normal behavior for a LAN Failover
  2. Switch ports are configured with different VLANs
  3. Portfast is not enabled on the switch ports
  4. One of the network interfaces has a bad patch cable.

Answer(s): B

Explanation:

switch ports are configured with different VLANs could be the cause of this error. If the switch ports are not configured with the same VLANs as the network interfaces on each node, then there could be a mismatch in network connectivity when one interface is disconnected1. This could affect the guest VMs that are using a different VLAN than the hypervisor.



What is the minimum time a newly created Deduplication storage policy takes to apply to the VMs in the container?

  1. 5 Minutes
  2. 10 minutes
  3. 30 minutes
  4. 60 minutes

Answer(s): C



Refer to the exhibit.



An administrator is adding a new node to a cluster. The node has been imaged to the same versions of AHV and AOS that the cluster running, configured with appropriate IP addresses, and br0-up has been configured the same the existing uplink bonds

When attempting to add the node to the cluster with the Expand Cluster function in Prism , the cluster is unable to find the new node.

Based on the above output from the new node, what is most likely the cause of this issue?

  1. The ports on the upstream switch are not configured for LACP.
  2. The existing and the expansion node are on different VLANs.
  3. There is a firewall blocking the discovery traffic from the tlu
  4. LACP configuration must be completed after cluster expansion

Answer(s): B