Free PEGAPCRSA80V1_2019 Exam Braindumps (page: 4)

Page 3 of 16

During application discovery of a Clarify application, you determine that the user accesses more than one customer case concurrently within the application, which creates multiple windows of the same type. This requires you to enable the UseKeys property on an application’s object.

Based on the image that shows the application and the matched controls in the Object Explorer, which control’s UseKeys property must be set to True?

  1. ClarifyCRM
  2. MdiClient
  3. _Case_1
  4. Control

Answer(s): A


Reference:

https://community.pega.com/knowledgebase/articles/how-do-i-use-keys-navigate-between-multiple-instances-object



There are two basic types of automations: events and procedures.
Which three statements describe a procedure automation? (Choose three.)

  1. It performs business logic and may interact with applications.
  2. It is triggered by a user or application action.
  3. It may contain more than one starting block.
  4. It contains an entry point and should contain at least one exit point.
  5. It should return a string value for messaging.

Answer(s): C,D,E



You created an RDA solution for a company that uses an application bar with various buttons that trigger robotic automations. Some of the users complained that the application bar often locks up during automation processing. Others complained that the automations enter the same data two to three times each iteration.

You suspect that the users are triggering the crashes and duplicate automation behavior by double-clicking the buttons on the application bar.

How do you resolve the situation?

  1. Hide the application bar as soon as the user clicks one of the buttons, and allow the application bar to reappear once the automation completes.
  2. After the initial click, disable the application bar buttons, display an automation progress bar, and then re- enable the buttons once the automation completes.
  3. Talk with the management team about the existing application bar behavior and user error at the company.
  4. Modify the automations so that they display a full message using the MessageManifest when the automations complete.

Answer(s): C



You have extracted a proxy for a data set and are using it to pass the data into a procedure automation input parameter. In the procedure automation, the data link from the input parameter is not connecting to the stringValue on a stringUtils method.

What two troubleshooting steps do you perform to correct the issue? (Choose two.)

  1. Confirm the proxy data in a messageDialog.
  2. Confirm the stringUtils method works.
  3. Confirm the data type on the procedure automation input parameter.
  4. Confirm the proxy’s data type matches with the stringUtils method.

Answer(s): A,C






Post your Comments and Discuss Pegasystems PEGAPCRSA80V1_2019 exam with other Community members:

PEGAPCRSA80V1_2019 Discussions & Posts