As part of an organization's IT security compliance requirement, NSX Manager must be configured for 2FA (two-factor authentication).
What should an NSX administrator have ready before the integration can be configured?

  1. Active Directory LDAP integration with ADFS
  2. VMware Identity Manager with NSX added as a Web Application
  3. VMware Identity Manager with an OAuth Client added
  4. Active Directory LDAP integration with OAuth Client added

Answer(s): B

Explanation:

To enable two-factor authentication (2FA) for NSX Manager, VMware Identity Manager must be configured and integrated with NSX. The NSX Manager should be added as a web application in VMware Identity Manager, which will allow 2FA to be applied during the authentication process. VMware Identity Manager supports 2FA methods, including integration with external identity providers, and it can manage access to NSX with additional security layers.



What should an NSX administrator check to verify that VMware Identity Manager integration is successful?

  1. From the NSX Ul the status of the VMv/are Identity Manager Integration must be Enabled'
  2. From the NSX CLI the status of the VMware Identity Manager Integration must be Configured'
  3. From VMware Identity Manager the status of the remote access application must be green
  4. From the NSX Ul the URI in the address bar must have locaMalstf part of it.

Answer(s): B

Explanation:

To verify that VMware Identity Manager integration is successful with NSX, the administrator should check the NSX UI for the integration status. If it is configured correctly, the status should be marked as "Enabled," indicating that the integration is active and functioning.



An administrator has been tasked with implementing the SSL certificates for the NSX Manager Cluster VIP.
Which is the correct way to implement this change?

  1. Send an API call to https://<nsx-mgr>/api/vl/cluster/api- certificate?action=set_cluster_certificate&certificate_id=<certificate_id>
  2. Send an API call to https://<nsx-
    mgr>/api/vl/node/services/http?action=apply_certificate&certificate_id=<certificate_id>
  3. SSH as admin into the NSX manager with the cluster VIP IP and run nsxcli cluster certificate node install <certificate_id>
  4. SSH as admin into the NSX manager with the cluster VIP IP and run nsxcli cluster certificate vip install <certificate_id>

Answer(s): D

Explanation:

To implement SSL certificates for the NSX Manager Cluster VIP, the correct method is to SSH into the NSX Manager (using the Cluster VIP IP) and run the nsxcli cluster certificate vip install <certificate_id> command. This command installs the SSL certificate for the VIP, ensuring that the cluster's SSL certificate is properly configured for secure communications.



An administrator wants to validate the BGP connection status between the Tier-0 Gateway and the upstream physical router.
What sequence of commands could be used to check this status on NSX Edge node?

  1. - enable <LR-D>
    - get vrf <ID>
    - show bgp neighbor
  2. - get gateways
    - vrf <number>
    - get bgp neighbor
  3. - set vrf <ID>
    - show logical-routers
    - show <LR-D> bgp
  4. - show logical-routers
    - get vrf
    - show ip route bgp

Answer(s): A

Explanation:

To validate the BGP connection status between the Tier-0 Gateway and the upstream physical router on an NSX Edge node, the correct sequence involves enabling the specific logical router (Tier-0 Gateway), checking the VRF (Virtual Routing and Forwarding) context, and then using the show bgp neighbor command to view the BGP session status.
enable <LR-D>: This command enables the logical router interface (Tier-0 Gateway) to access its configuration.
get vrf <ID>: This command checks the specific VRF (used for routing separation) to see the associated routing table.
show bgp neighbor: This command displays the status of the BGP connection, including details about the neighbor relationships and their state.



What is VMware's recommendation for the minimum MTU requirements when planning an NSX deployment?

  1. MTU should be set to 1700 or greater across the data center network including inter-data center connections.
  2. MTU should be set to 1500 or less only on inter-data center connections.
  3. Configure Path MTU Discovery and rely on fragmentation.
  4. MTU should be set to 1550 or less across the data center network including inter-data center connections.

Answer(s): A

Explanation:

VMware recommends setting the MTU (Maximum Transmission Unit) to 1700 or greater for NSX deployments. This is to ensure that the VXLAN encapsulation, which adds overhead to the original Ethernet frame, can be accommodated without fragmentation. This MTU requirement includes the entire data center network, including inter-data center connections, to ensure consistent communication across all network components involved in the NSX deployment.