Free 3V0-42.20 Exam Braindumps
Advanced Design VMware NSX-T Data Center Questions 16–20 (page: 5)

Updated On: 9-Feb-2026

An architect is helping an organization with the Physical Design of an NSX-T Data Center solution. This information was gathered during a workshop:
-Migrating existing data center to KVM hosts.
-Redundancy and high availability are required.
-No component can be a single point of failure.

Which selection should the architect recommend? (Choose the best answer.)

  1. Linux Bridge redundancy with Active/Active Mode and multiple pNICs with necessary binding
  2. Linux Bridge redundancy with Active/Active Mode and single pNIC with static binding
  3. vSS/vDS in Active/Standby Mode with necessary binding
  4. vSS/vDS in Active/Active Mode with necessary pNICS and required binding modes

Answer(s): C



An architect is helping an organization with the Conceptual Design of an NSX-T Data Center solution. This information was gathered by the architect during the Discover Task of the Engagement Lifecycle:

-There are applications which use IPv6 addressing.
-Network administrators are not familiar with NSX-T Data Center solutions.
-Hosts can only be configured with two physical NICs.
-There is an existing management cluster to deploy the NSX-T components.
-Dynamic routing should be configured between the physical and virtual network.
-There is a storage array available to deploy NSX-T components.

Which risk was documented by the architect? (Choose the best answer.)

  1. Network administrators are not familiar with NSX-T Data Center solutions.
  2. Dynamic routing should be configured between the physical and virtual network.
  3. There are applications which use IPv6 addressing.
  4. There is a storage array available to deploy NSX-T components.

Answer(s): B



An architect is helping an organization with the Physical Design of an NSX-T Data Center solution. This information was gathered during a workshop about ESXi Host networking:
-A total of 50 ESXi hosts to be configured as Transport Nodes.
-All ESXi hosts have a dedicated 2 × Intel 10Gbps Physical Network adapter for the Overlay Traffic.

To achieve low latency, high throughput, redundancy, and performance, which two NIC teaming policies should the architect recommend? (Choose two.)

  1. Load Balance Source MAC
  2. Load Balance Port ID
  3. Load Balance Source
  4. Load Balance Source Port ID
  5. Failover Order

Answer(s): D,E



Which two resources can be used by an NSX architect during the Assessment Phase? (Choose two.)

  1. vRealize Network Insight
  2. VMware Validated Design
  3. VMware customer references
  4. key stakeholder interviews
  5. application licensing

Answer(s): A,E



A customer wants to place their NSX Managers in different subnets.
Which would an architect recommend to support the request? (Choose the best answer.)

  1. Use a load balancer.
  2. Use round-robin DNS.
  3. Use NAT.
  4. Use a cluster Virtual IP.

Answer(s): D


Reference:

http://www.cloudxtreme.info/nsx-t-manager-clustering/



Viewing page 5 of 13
Viewing questions 21 - 25 out of 57 questions


Post your Comments and Discuss VMware 3V0-42.20 exam prep with other Community members:

AI Tutor AI Tutor 👋 I’m here to help!