Free 5V0-22.21 Exam Braindumps
VMware vSAN Specialist Questions 11–15 (page: 4)

Updated On: 9-Feb-2026

An organization is facing vSAN storage capacity challenges on one of their vSAN enabled clusters, while other vSAN enabled clusters are underutilized. The current vSAN version is 7.0 U1.
Which vSAN feature should be used to resolve this challenge in the quickest way?

  1. vSAN HCI Mesh
  2. vSAN Replication
  3. vSAN Stretched Clusters
  4. vSAN Datastore(s)

Answer(s): A


Reference:

https://docs.vmware.com/en/VMware-vSphere/7.0/rn/vmware-vsan-701-release-notes.html



An existing vSAN cluster has this specification:

-Four ESXi hosts with all flash configuration
-Each with two disk groups

Each disk group with one cache device and four capacity devices There are five more device slots available The CTO would like to provision new applications, and these will need more capacity and performance.
Which two methods may be used by the vSAN administrator to meet this goal? (Choose two.)

  1. Adding faster cache devices
  2. Adding one more disk group per host with the same configuration
  3. Replacing all cache devices by a larger device
  4. Adding an ESXi host with identical device configuration
  5. Replacing all capacity devices by a larger device

Answer(s): B,D


Reference:

https://core.vmware.com/resource/vmware-vsan-design-guide



An administrator has discovered that space utilized by VMs does not decrease after deleting files and folders within the VMs. The administrator needs to be able to reclaim this space.
Which action could the administrator take to accomplish this task?

  1. Disable Storage I/O Control for the vSAN cluster.
  2. Reboot the VM to recreate the swap file.
  3. Set the Object Space Reservation rule to 100%.
  4. Enable TRIM/UNMAP for the vSAN cluster.

Answer(s): D


Reference:

https://blogs.vmware.com/virtualblocks/2018/09/10/vmware-vsan-6-7u1-storage-reclamation-trim-unmap/



During yesterday’s business hours, a cache drive failed on one of the vSAN nodes. The administrator reached out to the manufacturer and received a replacement drive the following day. When the drive failed, vSAN started a resync to ensure the health of data, and all objects are showing a healthy and compliant state. The vSAN administrator needs to replace the failed cache drive.
Which set of steps should the vSAN administrator take?

  1. Remove the existing vSAN disk group, and physically replace the device. Then, check to verify that the ESXi host automatically detects the new device. Afterwards, manually recreate the Disk Group.
  2. Physically replace the failed cache device, and vSAN will automatically create a new disk group. Then, remove the disk group with the failed device.
  3. Physically replace the failed cache device, and vSAN will automatically allocate the storage. Then, rebalance the cache layer.
  4. Place the disk group into maintenance mode, and select Full Data Migration. Then, physically replace the failed cache device. Afterwards, vSAN will rebuild the disk group automatically.

Answer(s): B


Reference:

https://docs.vmware.com/en/VMware-vSphere/7.0/com.vmware.vsphere.vsan-monitoring.doc/GUID-95E5DAF9-FE36-497B-90B4- DB1CA05FE935.html



A vSphere administrator wants to use vSphere Lifecycle Manager (vLCM) to manage a vSAN cluster with one desired image. When creating the new cluster, the administrator chooses “Manage all hosts in the cluster with a single image”.
Which option is NOT available when setting up the cluster image?

  1. Import image from new host
  2. Import image from an existing host in the vCenter inventory
  3. Import baseline from vSphere Lifecycle Manager
  4. Compose a new image

Answer(s): D


Reference:

https://blogs.vmware.com/virtualblocks/2020/06/02/vsphere-lifecycle-manager-on-hpe/



Viewing page 4 of 17
Viewing questions 16 - 20 out of 76 questions


Post your Comments and Discuss VMware 5V0-22.21 exam prep with other Community members:

AI Tutor AI Tutor 👋 I’m here to help!