Free VMware 5V0-22.21 Exam Braindumps (page: 4)

A newly deployed vSAN cluster runs vSAN 7.0, and the vSAN cluster needs an integration with a third-party software solution. The software solution provides full app-level redundancy, and it runs on the vSAN Data Persistence platform.
The administrator configures vSAN Direct Configuration to integrate the third-party storage with vSAN and now needs to configure a storage policy to make sure the vSAN Direct storage is used by the vSAN Data Persistence platform third-party software solution.
Which type of storage policy configuration should the administrator use?

  1. A storage policy with tag or capability-based rules for vSAN Direct
  2. A storage policy with capability-based rules for third-party storage
  3. A vSAN shared nothing policy with no data redundancy (FTT=0)
  4. A vSAN storage policy with one failure to tolerate (FTT=1)

Answer(s): A



An Application Clustering Solution requires an in-guest attachable LUN which can be shared across two different VMs. Which vSAN feature can meet this requirement?

  1. vSAN Data Persistence
  2. vSAN iSCSI Target Service
  3. vSAN HCI Mesh
  4. vSAN Datastore Sharing

Answer(s): D


Reference:

https://docs.vmware.com/en/VMware-vSphere/7.0/vsan-703-administration-guide.pdf



An organization is facing vSAN storage capacity challenges on one of their vSAN enabled clusters, while other vSAN enabled clusters are underutilized. The current vSAN version is 7.0 U1.
Which vSAN feature should be used to resolve this challenge in the quickest way?

  1. vSAN HCI Mesh
  2. vSAN Replication
  3. vSAN Stretched Clusters
  4. vSAN Datastore(s)

Answer(s): A


Reference:

https://docs.vmware.com/en/VMware-vSphere/7.0/rn/vmware-vsan-701-release-notes.html



An existing vSAN cluster has this specification:

-Four ESXi hosts with all flash configuration
-Each with two disk groups

Each disk group with one cache device and four capacity devices There are five more device slots available The CTO would like to provision new applications, and these will need more capacity and performance.
Which two methods may be used by the vSAN administrator to meet this goal? (Choose two.)

  1. Adding faster cache devices
  2. Adding one more disk group per host with the same configuration
  3. Replacing all cache devices by a larger device
  4. Adding an ESXi host with identical device configuration
  5. Replacing all capacity devices by a larger device

Answer(s): B,D


Reference:

https://core.vmware.com/resource/vmware-vsan-design-guide



Viewing page 4 of 20
Viewing questions 13 - 16 out of 76 questions



Post your Comments and Discuss VMware 5V0-22.21 exam prep with other Community members:

5V0-22.21 Exam Discussions & Posts