-- Exhibit --



-- Exhibit --

A vSphere administrator assigns VLAN 3389 to the Production port group on the VCP_DCV_Example vSphere Distributed Switch. After the change, users report a loss of connectivity to their applications. Further analysis provides the following data:

· The cluster has not had a ESXi host failure.

· Application functioned normally prior to the change.

· The loss of connectivity occurred immediately following the change.

Which condition would cause this loss of connectivity?

  1. The physical switch ports used by the vmnics have not been configured with 802.1Q.
  2. Maintenance Mode was initiated on one of the hosts in the cluster. Connectivity will resume after the virtual machines are migrated.
  3. All uplinks were removed from the VCP_DCV_Example switch and added to another virtual switch.
  4. A load balancing setting on the port group conflicts with the load balancing setting of the switch.

Answer(s): A



Why would an administrator be unable to locate an IP address for a vSphere vmnic uplink?

  1. IP addresses are defined at the virtual nic level, not the vmnic level.
  2. ESXi host vmnics communicate with physical switches on layer 3.
  3. ESXi hosts use NAT translation to mask the actual vmnic IP address.
  4. The IP address of the vmnic is not shown in the vSphere Client.

Answer(s): A



Which database platform is embedded within the vApp architecture of vCenter Operations Manager?

  1. MySQL
  2. IBM DB2 Express
  3. Oracle 11g Express
  4. vPostgres

Answer(s): D



An administrator attempts to delete a Storage Policy and receives an error.

Which two object types, if assigned a Storage Policy, would prevent the Storage Policy from being deleted? (Choose two.)

  1. A virtual machine.
  2. A virtual disk.
  3. A datastore.
  4. A datastore cluster.

Answer(s): A,B



An administrator has configured hardware acceleration for a Fibre Channel storage array. After a recent maintenance event, the administrator finds that cloning and migration operations are taking excessively long to complete.

Which two settings could cause hardware acceleration to become disabled? (Choose two.)

  1. VAAI Plugin Name = VMW_VAAIP_SYM
  2. VAAI Plugin Name = VMW_VAAIP_NETAPP
  3. VMFS3.HardwareAcceleratedLocking = 0
  4. Datamover.HardwareAcceleratedInit = 0

Answer(s): C,D