What is required for using Puppet in a Cisco NX-OS environment?
Answer(s): D
Puppet agents cannot run natively on Cisco Nexus 7000 and Cisco Nexus 7700 switches. Instead, they run in a special virtual environment called the Open AgentContainer (OAC).
https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus7000/sw/programmability/guide/b_Cisco_Nexus_7000_Series_NX-OS_Programmability_Guide/b_Cisco_Nexus_7000_Series_NX-OS_Programmability_Guide_chapter_01001.pdf
Refer to the exhibit.Why does the Python code for Cisco NX-API print an error message?
Commands that belong to different message types should not be mixed. For example, show commands are cli_show message type and are not supported in cli_conf mode.
https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus7000/sw/programmability/guide/cisco_nexus7000_programmability_guide_8x/b- cisco-nexus7000-programmability-guide-8x_chapter_011.html
Which two components should be checked when a Cisco Nexus 9000 Series Switch fails to boot using POAP? (Choose two.)
Answer(s): B,E
PowerOn Auto Provisioning (POAP) automates the process of upgrading software images and installing configuration files on devices that are being deployed in the network for the first time.When a device with the POAP feature boots and does not find the startup configuration, the device enters POAP mode, locates a DHCP server, and bootstraps itself with its interface IP address, gateway, and DNS server IP addresses. The device also obtains the IP address of a TFTP server and downloads a configuration script that enables the switch to download and install the appropriate software image and configuration file.
https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/7-x/fundamentals/configuration/guide/b_Cisco_Nexus_9000_Series_NX-OS_Fundamentals_Configuration_Guide_7x/b_Cisco_Nexus_9000_Series_NX-OS_Fundamentals_Configuration_Guide_7x_chapter_0100.html
A POAP-enabled Cisco Nexus switch will not enter POAP mode.Which two conditions should be verified? (Choose two.)
Answer(s): A,B
POAP configuration guidelines and limitations are as follows:* The Cisco Nexus switch software image must support POAP for this feature to function.* POAP does not support provisioning of the switch after it has been configured and is operational. Only auto-provisioning of a switch with no startup configuration is supported.
https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus7000/sw/fundamentals/config/cisco_nexus7000_fundamentals_config_guide_8x/Using_PowerOn_Auto_Provisioning.html
An engineer enters these commands while in EEM on a Cisco Nexus 9000 Series Switch event manager applet Backup-config event timer watchdog time 1800 name timer event cli match "copy running-config startup-config"What is the result of applying this configuration?
See below for an example of the outcome:SwitchA# sh ver | inc image -NXOS image file is: bootflash:///nxos.7.0.3.I7.10.binSwitchA# conf t -Enter configuration commands, one per line. End with CNTL/Z.SwitchA(config)# event manager applet Backup-configSwitchA(config-applet)# event timer watchdog time 1800 name timerConfiguration accepted successfullySwitchA(config-applet)# event cli match "copy running-config startup-config"SwitchA(config-applet)# end -SwitchA# copy running-config startup-config% Command blocked by event manager policy