Free PAM-SEN Exam Braindumps
CyberArk Sentry - PAM Questions 52–56 (page: 5)

Updated On: 31-Jan-2026

What is required before the first CPM can be installed?

  1. The environment must have at least one Vault and one PVWA installed.
  2. The Vault environment must have at least one account stored in a safe.
  3. Custom platforms must be downloaded from the CyberArk Marketplace.
  4. The PSM component must be installed and proper functionality validated.

Answer(s): A



You are installing the HTML5 gateway on a Linux host using the RPM provided.
After installing the Tomcat webapp, what is the next step in the installation process?

  1. Deploy the HTML5 service (guacd).
  2. Secure the connection between the guacd and the webapp.
  3. Secure the webapp and JWT validation endpoint.
  4. Configure ASLR.

Answer(s): A



As a member of a PAM Level-2 support team, you are troubleshooting an issue related to load balancing four PVWA servers at two data centers. You received a note from your Level-1 support team stating “When testing PVWA website from a workstation, we noticed that the “Source IP of last sign-in” was shown as the VIP (Virtual IP address) assigned to the four PVWA servers instead of the workstation IP where the PVWA site was launched from.”
Which step should you take?

  1. Verify the “LoadBalancerClientAddressHeader” parameter setting in PVWA configuration file Web.config is set to “X-Forwarded-For”.
  2. Add the VIP (Virtual IP address) assigned to the four PVWA servers to the certificates issued for all four PVWA servers, if missing.
  3. Add a firewall rule to allow the testing workstation to connect to the VIP (Virtual IP address) assigned to the four PVWA servers on Port TCP 443.
  4. Edit the dbparm.ini file on the Vault server and add the IP or subnet of the workstation to the whitelist.

Answer(s): A



Which statement is correct about a post-install hardening?

  1. The Vault must be hardened during the Vault installation process.
  2. After the Vault server is installed, you must join the server to the Enterprise Domain and reboot the host.
  3. It is executed after Vault installation by running CAVaultHarden.exe and hardening options can be edited by changing the Hardening.ini file.
  4. If it is mandated by an organization’s IT governance, you do not have to execute Vault hardening; however, server hardening cannot be reversed.

Answer(s): C



Which files does the Vault Installation Wizard prompt you for during the Vault install?

  1. Operator CD and License
  2. Master CD and License
  3. Operator CD and Vault Certificate
  4. Master CD and DBparm.ini

Answer(s): A



Viewing page 5 of 21
Viewing questions 21 - 25 out of 155 questions


Post your Comments and Discuss CyberArk PAM-SEN exam prep with other Community members:

AI Tutor AI Tutor 👋 I’m here to help!