Free 201 Exam Braindumps
TMOS Administration Questions 81–85 (page: 18)

Updated On: 9-Feb-2026

A virtual server is listening at 10.10.1.100:80 and has the following iRule associated with it:
When HTTP_REQUEST { if {[HTTP::uri] ends_with "txt" } { pool pool1 } elseif {[HTTP::uri]
ends_with "php" } { pool pool2 } If a user connects to http://10.10.1.100/foo.html, which pool will receive the request.

  1. pool1
  2. pool2
  3. None. The request will be dropped.
  4. Unknown. The pool cannot be determined from the information provided.

Answer(s): D



A virtual server is listening at 10.10.1.100:any and has the following iRule associated with it:
When CLIENT_ACCEPTED { if {[TCP::local_port] equals 80 } { pool pool1 } elseif {[TCP::local_port] equals 443 } { pool pool2 } If a user connects to 10.10.1.100 and port 22, which pool will receive the request.

  1. pool1
  2. pool2
  3. None. The request will be dropped.
    34
  4. Unknown. The pool cannot be determined from the information provided.

Answer(s): D



Which statement is true about the synchronization process, as performed by the Configuration Utility or by typing b config sync all.

  1. The process should always be run from the standby system.
  2. The process should always be run from the system with the latest configuration.
  3. The two /config/bigip.conf configuration files are synchronized (made identical) each time the process is run.
  4. Multiple files, including /config/bigip.conf and /config/bigip_base.conf, are synchronized (made identical) each time the process is run.

Answer(s): C



Which statement is true concerning the default communication between a redundant pair of BIG‐IP devices?

  1. Communication between the systems cannot be effected by port lockdown settings.
  2. Data for both connection and persistence mirroring are shared through the same TCP connection.
  3. Regardless of the configuration, some data is communicated between the systems at regular intervals.
  4. Connection mirroring data is shared through the serial fail‐over cable unless network failover is enabled.

Answer(s): B



When upgrading a BIG‐IP redundant pair, what happens when one system has been updated but the other has not?

  1. Synching should not be performed.
  2. The first system to be updated will assume the Active role.
  3. This is not possible since both systems are updated simultaneously.
  4. The older system will issue SNMP traps indicating a communication error with the partner.

Answer(s): A