Free HCE-5920 Exam Braindumps
Hitachi Vantara Certified Specialist - Pentaho Data Integration Implementation Questions 21–25 (page: 6)

Updated On: 9-Feb-2026

You are encryption your database connection password to use in the kettle. properties file. The output of the encr script is:
Encrypted XYZabc123
In this scenario, which syntax is correct?

  1. DB_PASSWORD=Encfypted("XYZABC 123*)
  2. DB_PASSWORD=StringrXYZABC123")
  3. DB_PASSWORD-XYZABC123
  4. DB_PASSWORD-Encrypted XY2ABC123

Answer(s): A



You have a PDI job that gets a list of variables followed by three subsequent transformation entries.

Since the three subsequent transformation entries are not dependent on each other. You want to execute them at the same time.
According the Hitachi Vantara best practices, how do you accomplish this task?

  1. Select the Run Next Entries in Parallel option for the job entry that gathers variables.
  2. Select the Run Next Entries in Parallel option for the three independent transformation entries.
  3. Select the Enable Downstream setting from the Hop Bulk Change submenu.
  4. Increase the Change Number of Copies to Start option on the input step of each of the subsequent transformations.

Answer(s): B



You have a PDI job where you want to dynamically pass a table name to the Table input step of a transformation. You have replaced the table name reference in the transformation's Table input step with $(table_name)' but when the transformation runs the table name is shown as `$(table_name); Which action will correct this issue?

  1. Add a transformation entry in the job that uses the Get Variables step.
  2. Add a transformation entry in the job that sets the table-name variable.
  3. Change the reference in the Table input step to `?'
  4. Add a Set Variable step before the Table input step in the transformation.

Answer(s): D



An existing PDI job that checks the availability of a Web service is a sending a failure email even when the Web service is available.
You want this failure email to be sent only when the Web service is unavailable.
What should you do on tie hop between me two entries?

  1. Flip the direction
  2. Set the hop Evaluation option to Follow When.
  3. Set the hop Evaluation option to Follow When Result a True.
  4. Set the hop Evaluation option to Unconditional.

Answer(s): A



You are running a PDI Job and you need to identify when something fails for a specific job entry to notify the sysops team about the failure.
Which statement is correct in this scenario?

  1. Define the true evaluation hop out of the job entry that you are going to verify.
  2. Define the false evaluation hop out of the job entry that you are going to verify.
  3. Define the unconditional evaluation hop out of the job entry that you are going to verify.
  4. Do not define any evaluation hop out of the Job entry that are going to verify.

Answer(s): D



Viewing page 6 of 13
Viewing questions 26 - 30 out of 60 questions


Post your Comments and Discuss Hitachi HCE-5920 exam prep with other Community members:

AI Tutor AI Tutor 👋 I’m here to help!