Free CT-TAE Exam Braindumps

A defect in a SUT has been resolved and validated by an automated defect re-test in the current release of the software. This retest has now been added to the automated regression test suite.

Which statement BEST describes a reason why this defect could re-occur in future releases?

  1. Automated defect confirmation testing is not effective at confirming that the resolved defect will continue to work in future releases
  2. The configuration management process does not properly control the synchronization between software archives
  3. The automated regression test suite is not run consistently for future releases.
  4. The automated regression test suite has a narrower scope of functionality

Answer(s): B



Consider a SUT that small run on multiple platform during the execution of automated test runs. In each test run an automated test suite needs to be executed, with the same version of the TAF, against the same version of the SUT of each platform. Each platform shall have its own dedicated test environment. Your goal is to implement a process as automated as possible ( i.e with minimal manual intervention) that allows implementing a consistent setup of the TAS across the multiple test environments.

Which two of the following aspects are MOST relevant for achieving your goal in this scenario?

The configuration of the TAS uses automated installation scripts

The TAF saves the logs needed to debug errors in XML format

C) Features of the TAF not used by the automated tests have been tested

D) All the automated test cases contain the expected results

E) The TAS components are under configuration management

  1. A and e
  2. B and c
  3. B and d
  4. A and d

Answer(s): A



Consider a TAS that exclusively uses the APIs of a SUT. To make this work, significant changes have been required to the SUT by adding a set of dedicated test interfaces to the APIs. All the automated tests will use these test interfaces when interacting with the SUT. Assume that you are currently verifying the correctness of the automated test environment and test tool setup.

Which of the following would you expect to be the MOST specific risk associated with this scenario?

  1. The connectivity from the TAS to the dedicated test interfaces will not work
  2. The process of configuring the TAS will be error-phone due to manual intervention
  3. The automated test cases will not contain the expected result
  4. False alarms, that are unlikely to occur in the real world, will be observed during testing

Answer(s): D



Your goal is to verify completeness, consistency and correct behavior of an automated test suite. The TAS has been proven to successfully install in the SUT environment. All the preliminary checks to verify the correct functioning of the automated test environment and test tool configuration, installation and setup have successfully completed.

Which of the following is NOT a relevant check for achieving your goal in this scenario?

  1. Checking whether all the test cases contain the expected results
  2. Checking whether the post condition have been fulfilled for all the test cases
  3. Checking whether the loading of the TAS is repeatable in the SUT environment
  4. Checking whether all the test cases produce repeatable outcomes

Answer(s): D






Post your Comments and Discuss ISTQB® CT-TAE exam with other Community members:

CT-TAE Discussions & Posts