Free NS0-592 Exam Braindumps (page: 8)

Page 7 of 17

A customer’s FAS8200 node1 went down an hour ago after a WAFL inconsistency error. All data is being served from partner node2, but the storage failover show command output is not showing a node1 as “Waiting for giveback”.

What is the corrective action for this situation?

  1. Re-create the root aggregate on node1.
  2. Boot the system and run the wafliron command on the inconsistent data aggregate.
  3. From the LOADER prompt, run the wafliron command on the system’s root aggregate.
  4. Boot the system and run the WAFL_check command on the inconsistent data aggregate.

Answer(s): A



Click the exhibit button.


A customer is reporting that numbers in the statistics volume show command output appear to be incorrect.

Referring to the exhibit, which statement is correct?

  1. The problem is due to a difference in operation size.
  2. Perfstat should be used to explain the behavior.
  3. There are operation types that are not listed in the output.
  4. A case with NetApp should be raised to find the root cause.

Answer(s): A



You are investigating a CIFS issue at a customer site, but it is unclear which SMB version is being used between the client and the server. The customer has provided you with a packet trace output.

In this scenario, which packet exchange contains information to indicate which SMB version was agreed upon by the client and the server?

  1. Ioct1 Request FSCTL_DFS_GET_REFERRALSIoct1 Response FSCTL_DFS_GET_REFERRALS
  2. Session Setup Request Session Setup Response
  3. Negotiate Protocol RequestNegotiate Protocol Response
  4. Tree Connect Request TreeTree Connect Request Response

Answer(s): D



Click the exhibit button.


A customer reports that when they are failing over Hyper-V VMs, the process fails, and the server reports an error that indicates that there is something wrong with the storage.

Referring to the exhibit, which three actions would be required in ONTAP to solve this problem? (Choose three.)

  1. Verify that the -symlink-properties parameter is enabled on the share.
  2. Verify that the access-based-enumeration share parameter is configured.
  3. Verify that the continuously -available share parameter is configured.
  4. Verify that -offline-files parameter is set to manual on the share.
  5. Verify that the oplocks share property is configured.

Answer(s): B,C,E






Post your Comments and Discuss Network Appliance NS0-592 exam with other Community members:

NS0-592 Exam Discussions & Posts