Free NCS-CORE Exam Braindumps (page: 4)

Page 4 of 49

A consultant is onsite with a customer running Foundation VM (FVM) and discovers that there is no connectivity between the FVM and their laptop. The consultant verifies the following:

* The consultant's laptop and Nutanix nodes are plugged into a flat switch.

* The laptop, switch and nodes are plugged into supported power supplies.

* The laptop network adapters and FVM are configured with their corresponding IP addresses.

What is the cause for the connectivity failure to the FVM?

  1. The switch is not plugged into the power supply.
  2. Desktop Firewall is blocking ping requests.
  3. Network cables are not connected.
  4. Laptop WiFi configured to use DHCP.

Answer(s): B



An administrator has a custom backup application that requires a 2TB disk and runs in Windows. Throughput is considerably lower than expected.

The application was installed on a VM with the following configuration:

· Four vCPUs with one core/vCPU

· 4GB of Memory

· One 50GB vDisk for the Windows installation

· One 2TB vDisk for the application

What is the recommended configuration change to improve throughput?

  1. Increase the number of cores per vCPU
  2. Increase the vCPUs assigned to the VM
  3. Span the 2TB disk across four vDisks
  4. Add 4GB of memory to the VM

Answer(s): C



A consultant runs the Foundation Applet and discovers all the nodes. The consultant wants to use the latest version of Foundation for imaging for support purposes and to cover the latest hardware and software hypervisor support.

What should the consultant do to upgrade Foundation on a node?

  1. Use crash cart and manually upgrade Foundation files on one node.
  2. Use latest version of Foundation to reimage all the nodes.
  3. Use the Foundation VM to upgrade Foundation on all nodes.
  4. Use the Foundation Applet to upgrade Foundation on a single node.

Answer(s): D



An administrator needs to initiate a new VDI project within a couple of months. Prism Central reports there are no storage resources to accommodate such workloads.

The administrator sees many powered-off VMs and has the authority to delete test VMs powered off at least for 30 days. Test VMs belong to the Test category.

Using Prism Central, which steps are required to identify the correct VMs tobe deleted?

  1. Use Capacity Runway to filter by Test and Powered-off VMs
  2. Filter VMs list, choose Test category and Inactive under Efficiency
  3. Create a new Scenario selecting Test VMs. filter by uptime
  4. Create a new Project selecting Test VMs, sorting by power state

Answer(s): B



Page 4 of 49



Post your Comments and Discuss Nutanix NCS-CORE exam with other Community members:

hanaa commented on October 03, 2023
is this dump still valid???
Anonymous
upvote

hanaa commented on October 03, 2023
Is this dump still valid???
Anonymous
upvote