Free LEED-AP-Homes Exam Braindumps
LEED AP Homes (Residential) Questions 31–35 (page: 8)

Updated On: 7-Mar-2026

Minimum outdoor air ventilation in a LEED for Homes project is addressed by which of the following standards?

  1. IECC 2012
  2. ENERGY STAR for Homes
  3. ASHRAE Standard 62.2-2010
  4. ASHRAE Standard 90.1-2010

Answer(s): C

Explanation:

The LEED for Homes Rating System (v4) addresses minimum outdoor air ventilation requirements in the Indoor Environmental Quality (EQ) Prerequisite: Ventilation, which ensures adequate indoor air quality through proper ventilation design.
According to the LEED Reference Guide for Homes Design and Construction (v4):
EQ Prerequisite: Ventilation
Meet the minimum outdoor air ventilation requirements of ASHRAE Standard 62.2-2010, Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings. This standard specifies minimum ventilation rates and other measures to provide acceptable indoor air quality in residential buildings. Source: LEED Reference Guide for Homes Design and Construction, v4, Indoor Environmental Quality Prerequisite: Ventilation, p. 142.
The LEED v4.1 Residential BD+C rating system confirms:
EQ Prerequisite: Ventilation
Comply with ASHRAE Standard 62.2-2010 for minimum outdoor air ventilation rates in single-family and low-rise multifamily homes to ensure healthy indoor air quality. Source: LEED v4.1 Residential BD+C, Credit Library, accessed via USGBC LEED Online. The correct answer is ASHRAE Standard 62.2-2010 (Option C), as it is the specific standard referenced for minimum ventilation requirements in LEED for Homes.
Why not the other options?
A . IECC 2012: The International Energy Conservation Code (IECC) 2012 focuses on energy efficiency, not ventilation standards.


Reference:

LEED Reference Guide for Homes Design and Construction, v4, Energy and Atmosphere Prerequisite: Minimum Energy Performance, p. 112 (references IECC for energy, not ventilation). B . ENERGY STAR for Homes: While ENERGY STAR includes ventilation requirements, it references ASHRAE 62.2-2010, not a standalone standard.
LEED Reference Guide for Homes Design and Construction, v4, EQ Prerequisite:
Ventilation, p. 142.
D . ASHRAE Standard 90.1-2010: This standard applies to commercial buildings' energy performance, not residential ventilation.
LEED Reference Guide for Homes Design and Construction, v4, no mention of ASHRAE 90.1 for residential ventilation.
The LEED AP Homes Candidate Handbook emphasizes EQ prerequisites, including ventilation standards, and references the LEED Reference Guide for Homes Design and Construction as a key resource. The exam is based on LEED v4, ensuring the relevance of ASHRAE 62.2-2010.

LEED Reference Guide for Homes Design and Construction, v4, USGBC, Indoor Environmental Quality Prerequisite: Ventilation, p. 142.
LEED v4.1 Residential BD+C, USGBC LEED Credit Library, accessed via LEED Online (https://www.usgbc.org/credits).
LEED AP Homes Candidate Handbook, GBCI, October 2024, p. 12 (references study resources and exam scope based on LEED v4).
USGBC LEED for Homes Rating System (v4), available via USGBC website (https://www.usgbc.org/resources/leed-homes-design-and-construction-v4). LEED v4.1 for Homes, USGBC, accessed via LEED Online, confirming ASHRAE 62.2-2010.



Which of the following measures is a radon-resistant construction technique?

  1. Vent pipe to exhaust gases from under the home
  2. Pressurized basement or crawlspace to prevent gases from entering the home
  3. Perforated foundation slab to allow air circulation
  4. Continuously operating bath fans to remove gases from inside the home

Answer(s): A

Explanation:

The LEED for Homes Rating System (v4) includes the Indoor Environmental Quality (EQ) Credit:
Radon Control, which promotes radon-resistant construction techniques to mitigate the health risks of radon gas, a naturally occurring radioactive gas that can accumulate in homes. According to the LEED Reference Guide for Homes Design and Construction (v4):
EQ Credit: Radon Control (1 point)
Install a passive or active radon-resistant system, including a vent pipe extending from below the foundation (e.g., sub-slab or crawlspace) to the roof to exhaust radon gases before they enter the home. This is a primary radon-resistant construction technique. Source: LEED Reference Guide for Homes Design and Construction, v4, Indoor Environmental Quality Credit: Radon Control, p. 150.
The LEED v4.1 Residential BD+C rating system confirms:
EQ Credit: Radon Control
A vent pipe to exhaust gases from under the home (e.g., sub-slab depressurization system) is a key radon-resistant technique, preventing radon entry into living spaces. Source: LEED v4.1 Residential BD+C, Credit Library, accessed via USGBC LEED Online. The correct answer is vent pipe to exhaust gases from under the home (Option A), as this is a standard radon-resistant technique, typically involving a sub-slab depressurization system with a vent pipe.
Why not the other options?
B . Pressurized basement or crawlspace to prevent gases from entering the home: Pressurization can reduce infiltration but is not a standard radon-resistant technique; depressurization (via venting) is preferred.


Reference:

LEED Reference Guide for Homes Design and Construction, v4, EQ Credit: Radon Control, p. 150.

C . Perforated foundation slab to allow air circulation: Perforated slabs are not a recognized radon- resistant method; they may increase radon entry by allowing gas to flow into the home.
LEED Reference Guide for Homes Design and Construction, v4, EQ Credit: Radon Control, p. 150.
D . Continuously operating bath fans to remove gases from inside the home: Bath fans address general ventilation, not radon-specific mitigation, which requires sub-slab venting.
LEED Reference Guide for Homes Design and Construction, v4, EQ Credit: Enhanced Ventilation, p. 146.
The LEED AP Homes Candidate Handbook emphasizes EQ credits, including radon control, and references the LEED Reference Guide for Homes Design and Construction as a key resource. The exam is based on LEED v4, ensuring the relevance of vent pipe systems.

LEED Reference Guide for Homes Design and Construction, v4, USGBC, Indoor Environmental Quality Credit: Radon Control, p. 150.
LEED v4.1 Residential BD+C, USGBC LEED Credit Library, accessed via LEED Online (https://www.usgbc.org/credits).
LEED AP Homes Candidate Handbook, GBCI, October 2024, p. 12 (references study resources and exam scope based on LEED v4).
USGBC LEED for Homes Rating System (v4), available via USGBC website (https://www.usgbc.org/resources/leed-homes-design-and-construction-v4). LEED v4.1 for Homes, USGBC, accessed via LEED Online, confirming radon-resistant techniques.



A project team wants to earn credit for Location and Transportation Credit, Site Selection, Option 3:
Open Space. A qualifying lot should be located within:

  1. 1/2 mi. (0.8 km) of a 3/4 acre (0.3 hectare) cornfield
  2. 3/4 mi. (1.2 km) of a publicly accessible park that is 3/4 acre (0.3 hectare) in size
  3. 1/2 mi. (0.8 km) of a pond surrounded by a 1/2 acre (0.2 hectare) walkway, and across the street from a 1/4 acre (0.1 hectare) publicly accessible park
  4. 3/4 mi. (1.2 km) of a 1/4 acre (0.1 hectare) publicly accessible park, across the street from a 1/4 acre (0.1 hectare) lot which is private land open to the public

Answer(s): C

Explanation:

The LEED for Homes Rating System (v4) includes the Location and Transportation (LT) Credit: Site Selection, Option 3: Open Space, which encourages projects to be located near publicly accessible open spaces to promote recreation and environmental benefits. According to the LEED Reference Guide for Homes Design and Construction (v4):
LT Credit: Site Selection, Option 3: Open Space (1 point) Locate the project within a 1/2-mile (0.8-kilometer) walking distance of a publicly accessible open space that is at least 0.75 acre (0.3 hectare) in size. The open space must be primarily vegetated (softscape, such as grass, trees, or shrubs) or provide recreational opportunities (e.g., playgrounds, trails). Acceptable open spaces include parks, playgrounds, or nature preserves, but not water bodies or privately restricted areas.
Source: LEED Reference Guide for Homes Design and Construction, v4, Location and Transportation Credit: Site Selection, p. 55.
The LEED v4.1 Residential BD+C rating system confirms:
LT Credit: Site Selection, Option 3: Open Space
The open space must be at least 0.75 acre (0.3 hectare), publicly accessible, and within 1/2 mile (0.8 km) of the project. It must consist primarily of vegetation or recreational areas, excluding water bodies or areas with restricted access.
Source: LEED v4.1 Residential BD+C, Credit Library, accessed via USGBC LEED Online.
Evaluation of options:
A . 1/2 mi. (0.8 km) of a 3/4 acre (0.3 hectare) cornfield: A cornfield is agricultural land, not a publicly accessible recreational or vegetated open space as defined by LEED, so it does not qualify.

B . 3/4 mi. (1.2 km) of a publicly accessible park that is 3/4 acre (0.3 hectare) in size: The distance (3/4 mi.) exceeds the 1/2-mile (0.8 km) requirement, so it does not qualify. C . 1/2 mi. (0.8 km) of a pond surrounded by a 1/2 acre (0.2 hectare) walkway, and across the street from a 1/4 acre (0.1 hectare) publicly accessible park: The pond is excluded (water bodies do not qualify), and the walkway (0.2 hectare) and park (0.1 hectare) together total 0.3 hectare (0.75 acre), meeting the size requirement within 1/2 mile. Assuming the walkway is vegetated or recreational, this qualifies.
D . 3/4 mi. (1.2 km) of a 1/4 acre (0.1 hectare) publicly accessible park, across the street from a 1/4 acre (0.1 hectare) lot which is private land open to the public: The distance (3/4 mi.) exceeds 1/2 mile, and the combined area (0.2 hectare) is below 0.3 hectare. Private land, even if publicly accessible, may not fully qualify without clear documentation. The correct answer is Option C, as it meets the 1/2-mile distance and the combined 0.75-acre size requirement, assuming the walkway is vegetated or recreational. The LEED AP Homes Candidate Handbook emphasizes LT credits, including Site Selection, and references the LEED Reference Guide for Homes Design and Construction as a key resource. The exam is based on LEED v4, ensuring the relevance of open space criteria.


Reference:

LEED Reference Guide for Homes Design and Construction, v4, USGBC, Location and Transportation Credit: Site Selection, p. 55.
LEED v4.1 Residential BD+C, USGBC LEED Credit Library, accessed via LEED Online (https://www.usgbc.org/credits).
LEED AP Homes Candidate Handbook, GBCI, October 2024, p. 12 (references study resources and exam scope based on LEED v4).
USGBC LEED for Homes Rating System (v4), available via USGBC website (https://www.usgbc.org/resources/leed-homes-design-and-construction-v4). LEED v4.1 for Homes, USGBC, accessed via LEED Online, confirming open space criteria.



As a prerequisite for Education of the Homeowner, Tenant, or Building Manager, the operations and maintenance manual must include which of the following?

  1. A set of building plans
  2. A list of local services including a map
  3. Product manuals for installed equipment
  4. Chemical analysis of domestic water supply

Answer(s): C

Explanation:

The question references an "Energy and Atmosphere Prerequisite" for homeowner education, which appears to be a misnomer, as the LEED for Homes Rating System (v4) includes this requirement under the Innovation (IN) Prerequisite: Education of the Homeowner, Tenant, or Building Manager. This prerequisite ensures occupants are educated on the home's sustainable features and maintenance needs.

According to the LEED Reference Guide for Homes Design and Construction (v4):
IN Prerequisite: Education of the Homeowner, Tenant, or Building Manager Provide an operations and maintenance manual that includes product manuals for installed equipment (e.g., HVAC, water heating, renewable energy systems) to guide homeowners or tenants in proper operation and maintenance of green features. Source: LEED Reference Guide for Homes Design and Construction, v4, Innovation Prerequisite:
Education of the Homeowner, Tenant, or Building Manager, p. 188. The LEED v4.1 Residential BD+C rating system confirms:
IN Prerequisite: Education of the Homeowner or Tenant
The operations and maintenance manual must include product manuals for all installed equipment to ensure proper use and upkeep of sustainable systems. Source: LEED v4.1 Residential BD+C, Credit Library, accessed via USGBC LEED Online. The correct answer is product manuals for installed equipment (Option C), as these are required in the operations and maintenance manual to support homeowner education.
Why not the other options?
A . A set of building plans: While useful, building plans are not a required component of the operations and maintenance manual.


Reference:

LEED Reference Guide for Homes Design and Construction, v4, IN Prerequisite: Education of the Homeowner, Tenant, or Building Manager, p. 188. B . A list of local services including a map: This is relevant to LT Credit: Community Resources and Services, not the homeowner education prerequisite.
LEED Reference Guide for Homes Design and Construction, v4, LT Credit: Community Resources and Services, p. 56.
D . Chemical analysis of domestic water supply: Water quality analysis may be relevant for health but is not required in the operations and maintenance manual.
LEED Reference Guide for Homes Design and Construction, v4, IN Prerequisite: Education of the Homeowner, Tenant, or Building Manager, p. 188. The LEED AP Homes Candidate Handbook emphasizes IN prerequisites, including homeowner education, and references the LEED Reference Guide for Homes Design and Construction as a key resource. The exam is based on LEED v4, ensuring the relevance of product manuals.

LEED Reference Guide for Homes Design and Construction, v4, USGBC, Innovation Prerequisite:
Education of the Homeowner, Tenant, or Building Manager, p. 188. LEED v4.1 Residential BD+C, USGBC LEED Credit Library, accessed via LEED Online (https://www.usgbc.org/credits).
LEED AP Homes Candidate Handbook, GBCI, October 2024, p. 12 (references study resources and exam scope based on LEED v4).
USGBC LEED for Homes Rating System (v4), available via USGBC website (https://www.usgbc.org/resources/leed-homes-design-and-construction-v4). LEED v4.1 for Homes, USGBC, accessed via LEED Online, confirming manual requirements.



What are the benefits of rainwater harvesting in areas with substantial rainfall spikes?

  1. Helps to offset air pollution
  2. Helps to maintain required firewater levels
  3. Keeps water out of storm sewers
  4. Little-to-no benefit since precipitation is seasonal

Answer(s): C

Explanation:

The LEED for Homes Rating System (v4) addresses rainwater harvesting in the Sustainable Sites (SS) Credit: Rainwater Management, which aims to reduce runoff and manage stormwater on-site, particularly in areas with significant rainfall events. According to the LEED Reference Guide for Homes Design and Construction (v4):
SS Credit: Rainwater Management (1­3 points)
Implement rainwater harvesting systems (e.g., rain barrels, cisterns) to capture and store rainwater, reducing runoff volume and keeping water out of storm sewers. This is particularly beneficial in areas with substantial rainfall spikes, as it mitigates flooding and reduces strain on municipal stormwater systems.
Source: LEED Reference Guide for Homes Design and Construction, v4, Sustainable Sites Credit:
Rainwater Management, p. 76.
The LEED v4.1 Residential BD+C rating system confirms:
SS Credit: Rainwater Management
Rainwater harvesting reduces runoff by capturing water on-site, preventing it from entering storm sewers, which is especially effective during heavy rainfall events. Source: LEED v4.1 Residential BD+C, Credit Library, accessed via USGBC LEED Online. The correct answer is keeps water out of storm sewers (Option C), as rainwater harvesting captures runoff, reducing the burden on stormwater infrastructure, particularly in areas with seasonal or substantial rainfall spikes.
Why not the other options?
A . Helps to offset air pollution: Rainwater harvesting does not directly address air pollution; it focuses on water management.


Reference:

LEED Reference Guide for Homes Design and Construction, v4, SS Credit: Rainwater Management, p. 76.
B . Helps to maintain required firewater levels: Firewater systems are unrelated to rainwater harvesting, which is for non-potable uses like irrigation.

No mention in LEED v4 for Homes; irrelevant to rainwater management. D . Little-to-no benefit since precipitation is seasonal: Rainwater harvesting is highly beneficial during rainfall spikes, as it captures excess water for later use, contradicting this option.
LEED Reference Guide for Homes Design and Construction, v4, SS Credit: Rainwater Management, p. 76.
The LEED AP Homes Candidate Handbook emphasizes SS credits, including rainwater management, and references the LEED Reference Guide for Homes Design and Construction as a key resource. The exam is based on LEED v4, ensuring the relevance of rainwater harvesting benefits.

LEED Reference Guide for Homes Design and Construction, v4, USGBC, Sustainable Sites Credit:
Rainwater Management, p. 76.
LEED v4.1 Residential BD+C, USGBC LEED Credit Library, accessed via LEED Online (https://www.usgbc.org/credits).
LEED AP Homes Candidate Handbook, GBCI, October 2024, p. 12 (references study resources and exam scope based on LEED v4).

USGBC LEED for Homes Rating System (v4), available via USGBC website (https://www.usgbc.org/resources/leed-homes-design-and-construction-v4). LEED v4.1 for Homes, USGBC, accessed via LEED Online, confirming rainwater harvesting benefits.



Viewing page 8 of 21
Viewing questions 36 - 40 out of 100 questions


Post your Comments and Discuss US Green Building Council LEED-AP-Homes exam prep with other Community members:

AI Tutor AI Tutor 👋 I’m here to help!