How is credit earned under Regional Priority Credit, Regional Priority when the credit has multiple thresholds?

  1. Points are awarded at the minimum threshold
  2. Points are awarded at the maximum threshold
  3. Points are awarded when the maximum threshold has been exceeded
  4. Points are awarded at particular levels of achievement

Answer(s): C

Explanation:

The LEED for Homes Rating System (v4) includes Regional Priority (RP) Credits, which provide bonus points for achieving existing credits identified as environmentally significant for a project's region. For credits with multiple thresholds, exemplary performance can earn additional points. According to the LEED Reference Guide for Homes Design and Construction (v4):
Regional Priority Credits (1­4 points)
Regional Priority Credits are awarded for achieving designated credits that address location-specific environmental priorities. For credits with multiple thresholds (e.g., Water Efficiency Credit: Outdoor Water Use), an additional bonus point is awarded when the maximum threshold has been exceeded, demonstrating exemplary performance.
Source: LEED Reference Guide for Homes Design and Construction, v4, Regional Priority Credits, p.
190; Innovation Credit: Innovation, p. 190.
The LEED v4.1 Residential BD+C rating system confirms:
Regional Priority Credits
When an RP credit has multiple thresholds, a project earns the bonus point by meeting the base credit requirements, and an additional point may be earned for exemplary performance by exceeding the maximum threshold of the underlying credit. Source: LEED v4.1 Residential BD+C, Credit Library, accessed via USGBC LEED Online. The correct answer is points are awarded when the maximum threshold has been exceeded (Option

C), as RP credits with multiple thresholds award bonus points for exemplary performance beyond the highest threshold.
Why not the other options?
A . Points are awarded at the minimum threshold: RP credits require achieving the base credit, not just the minimum threshold.
B . Points are awarded at the maximum threshold: Points are awarded for exceeding the maximum threshold, not just meeting it.
D . Points are awarded at particular levels of achievement: This is too vague; exemplary performance beyond the maximum threshold is required.


Reference:

LEED Reference Guide for Homes Design and Construction, v4, Regional Priority Credits, p. 190.
The LEED AP Homes Candidate Handbook emphasizes RP credits and exemplary performance, referencing the LEED Reference Guide for Homes Design and Construction as a key resource. The exam is based on LEED v4, ensuring the relevance of exceeding thresholds.

LEED Reference Guide for Homes Design and Construction, v4, USGBC, Regional Priority Credits, p.
190; Innovation Credit: Innovation, p. 190.
LEED v4.1 Residential BD+C, USGBC LEED Credit Library, accessed via LEED Online (https://www.usgbc.org/credits).
LEED AP Homes Candidate Handbook, GBCI, October 2024, p. 12 (references study resources and exam scope based on LEED v4).
USGBC LEED for Homes Rating System (v4), available via USGBC website (https://www.usgbc.org/resources/leed-homes-design-and-construction-v4). LEED v4.1 for Homes, USGBC, accessed via LEED Online, confirming exemplary performance criteria.



In order for a project to earn Innovation Credit, LEED AP for Homes, the LEED AP for Homes must be a principal member of the:

  1. Project team and possess the credential prior to preliminary rating
  2. Project team and possess the credential prior to project registration
  3. Verification team and possess the credential prior to preliminary rating
  4. Verification team and possess the credential prior to project registration

Answer(s): B

Explanation:

The LEED for Homes Rating System (v4) includes the Innovation (IN) Credit: LEED Accredited Professional, which awards a point for having a LEED AP for Homes as a principal member of the project team to guide sustainable design and certification. According to the LEED Reference Guide for Homes Design and Construction (v4):
IN Credit: LEED Accredited Professional (1 point)
At least one principal participant of the project team must be a LEED AP for Homes and hold the credential prior to project registration. The LEED AP must be actively involved in the project to ensure effective implementation of LEED strategies.

Source: LEED Reference Guide for Homes Design and Construction, v4, Innovation Credit: LEED Accredited Professional, p. 189.
The LEED v4.1 Residential BD+C rating system confirms:
IN Credit: LEED Accredited Professional
The LEED AP for Homes must be a principal member of the project team (not the verification team) and possess the credential before project registration to earn the credit. Source: LEED v4.1 Residential BD+C, Credit Library, accessed via USGBC LEED Online. The correct answer is project team and possess the credential prior to project registration (Option B), as this meets the credit's requirements for the LEED AP's role and timing.
Why not the other options?
A . Project team and possess the credential prior to preliminary rating: The credential must be held before project registration, not preliminary rating.

C . Verification team and possess the credential prior to preliminary rating: The LEED AP must be on the project team, not the verification team.
D . Verification team and possess the credential prior to project registration: The LEED AP is part of the project team, not the verification team.


Reference:

LEED Reference Guide for Homes Design and Construction, v4, IN Credit: LEED Accredited Professional, p. 189.
The LEED AP Homes Candidate Handbook emphasizes IN credits, including the LEED AP role, and references the LEED Reference Guide for Homes Design and Construction as a key resource. The exam is based on LEED v4, ensuring the relevance of the project team requirement.

LEED Reference Guide for Homes Design and Construction, v4, USGBC, Innovation Credit: LEED Accredited Professional, p. 189.
LEED v4.1 Residential BD+C, USGBC LEED Credit Library, accessed via LEED Online (https://www.usgbc.org/credits).
LEED AP Homes Candidate Handbook, GBCI, October 2024, p. 12 (references study resources and exam scope based on LEED v4).
USGBC LEED for Homes Rating System (v4), available via USGBC website (https://www.usgbc.org/resources/leed-homes-design-and-construction-v4). LEED v4.1 for Homes, USGBC, accessed via LEED Online, confirming LEED AP requirements.



Which of the following team members must attend the entire meeting to earn the Trades Training Credit?

  1. Project architect
  2. Mechanical contractor
  3. Site supervisor or superintendent
  4. Air sealing and insulation contractor

Answer(s): B

Explanation:

The LEED for Homes Rating System (v4) includes the Integrative Process (IP) Credit: Integrative Process, Option 2: Trades Training, which requires training for key construction trades to ensure proper implementation of green building strategies.
According to the LEED Reference Guide for Homes Design and Construction (v4):
IP Credit: Integrative Process, Option 2: Trades Training (1 point) The mechanical contractor (responsible for HVAC systems) must attend the entire four-hour training session to ensure proper installation and operation of energy-efficient systems critical to LEED compliance. Other trades, such as air sealing and insulation contractors, are also encouraged but not explicitly required to attend the full session.
Source: LEED Reference Guide for Homes Design and Construction, v4, Integrative Process Credit:
Integrative Process, p. 45.
The LEED v4.1 Residential BD+C rating system confirms:
IP Credit: Integrative Process, Option 2: Trades Training

The mechanical contractor, as a key trade responsible for energy-related systems, must participate fully in the four-hour training to meet the credit requirements, ensuring expertise in sustainable HVAC installation.
Source: LEED v4.1 Residential BD+C, Credit Library, accessed via USGBC LEED Online. The correct answer is mechanical contractor (Option B), as their full attendance is critical due to the importance of HVAC systems in achieving LEED energy goals.
Why not the other options?
A . Project architect: Architects are part of the design team, not typically required for trades training. C . Site supervisor or superintendent: While important, they oversee general construction, not specific system installation.
D . Air sealing and insulation contractor: Their attendance is encouraged but not mandatory for the full session, unlike the mechanical contractor.


Reference:

LEED Reference Guide for Homes Design and Construction, v4, IP Credit: Integrative Process, p. 45.
The LEED AP Homes Candidate Handbook emphasizes IP credits, including trades training, and references the LEED Reference Guide for Homes Design and Construction as a key resource. The exam is based on LEED v4, ensuring the relevance of mechanical contractor attendance.

LEED Reference Guide for Homes Design and Construction, v4, USGBC, Integrative Process Credit:
Integrative Process, p. 45.
LEED v4.1 Residential BD+C, USGBC LEED Credit Library, accessed via LEED Online (https://www.usgbc.org/credits).
LEED AP Homes Candidate Handbook, GBCI, October 2024, p. 12 (references study resources and exam scope based on LEED v4).
USGBC LEED for Homes Rating System (v4), available via USGBC website (https://www.usgbc.org/resources/leed-homes-design-and-construction-v4). LEED v4.1 for Homes, USGBC, accessed via LEED Online, confirming trades training requirements.



A project team for a home in a small town is pursuing LEED certification. The home is designed with the following site characteristics:
· The lot is square.
· Three sides of the square lot border undeveloped land. · The previous home covering 78% of the lot is deconstructed and the new LEED home will be built in its place.
· One full side of the square lot borders a home that was built 10 years before the LEED project. Compliance with which of the following options, if any, will qualify the home for Location and Transportation Credit, Site Selection?

  1. Infill only
  2. Previously Developed only
  3. Infill and Previously Developed
  4. None, this home does not comply with Location and Transportation Credit, Site Selection

Answer(s): B

Explanation:

The LEED for Homes Rating System (v4) includes the Location and Transportation (LT) Credit: Site Selection, which awards points for building on infill or previously developed sites to minimize environmental impact.
According to the LEED Reference Guide for Homes Design and Construction (v4):
LT Credit: Site Selection (1­3 points)
Option 1: Infill: At least 75% of the lot's perimeter must border previously developed parcels (e.g., existing buildings or infrastructure).
Option 2: Previously Developed: The lot must have been previously altered by construction (e.g., a prior home covering a significant portion of the site) before the LEED project. A site with a previous home covering 78% of the lot qualifies as previously developed, but if only one side (25% of a square lot's perimeter) borders a developed parcel, it does not meet the infill requirement.
Source: LEED Reference Guide for Homes Design and Construction, v4, Location and Transportation Credit: Site Selection, p. 54.
The LEED v4.1 Residential BD+C rating system confirms:
LT Credit: Site Selection
A site qualifies for Option 2: Previously Developed if it was previously altered (e.g., a home covering 78% of the lot). Infill requires 75% of the perimeter to border developed land, which a square lot with only one developed side (25%) does not meet.
Source: LEED v4.1 Residential BD+C, Credit Library, accessed via USGBC LEED Online.
Evaluation:
Infill: The lot is square, with one side (25% of the perimeter) bordering a developed home. This does not meet the 75% perimeter requirement for infill.
Previously Developed: The previous home covered 78% of the lot, qualifying it as previously developed.
The correct answer is Previously Developed only (Option B), as the site meets the criteria for Option 2 but not Option 1.
Why not the other options?
A . Infill only: The site does not meet the 75% perimeter requirement for infill (only 25% borders developed land).
C . Infill and Previously Developed: The site does not qualify for infill, so it cannot meet both options. D . None, this home does not comply: The site qualifies for Previously Developed due to the prior home.


Reference:

LEED Reference Guide for Homes Design and Construction, v4, LT Credit: Site Selection, p.
54.
The LEED AP Homes Candidate Handbook emphasizes LT credits, including site selection, and references the LEED Reference Guide for Homes Design and Construction as a key resource. The exam is based on LEED v4, ensuring the relevance of previously developed sites.

LEED Reference Guide for Homes Design and Construction, v4, USGBC, Location and Transportation Credit: Site Selection, p. 54.
LEED v4.1 Residential BD+C, USGBC LEED Credit Library, accessed via LEED Online (https://www.usgbc.org/credits).
LEED AP Homes Candidate Handbook, GBCI, October 2024, p. 12 (references study resources and exam scope based on LEED v4).
USGBC LEED for Homes Rating System (v4), available via USGBC website

(https://www.usgbc.org/resources/leed-homes-design-and-construction-v4). LEED v4.1 for Homes, USGBC, accessed via LEED Online, confirming site selection criteria.



For a two-bedroom unit in a multi-family building, a kitchen's minimum airflow requirement for intermittent local exhaust is:

  1. 100 cfm (47 lps)
  2. 200 cfm (94 lps)
  3. 1 cfm per ft² (5.08 lps per m²)
  4. 2.5 cfm per ft² (12.7 lps per m²)

Answer(s): A

Explanation:

The LEED for Homes Rating System (v4) addresses kitchen ventilation requirements in the Indoor Environmental Quality (EQ) Prerequisite: Ventilation, which references ASHRAE Standard 62.2-2010 for minimum airflow rates in residential buildings, including multi-family units. According to the LEED Reference Guide for Homes Design and Construction (v4):
EQ Prerequisite: Ventilation
For intermittent local exhaust in kitchens, ASHRAE Standard 62.2-2010 requires a minimum airflow rate of 100 cfm (47 lps) for each kitchen to effectively remove cooking-related pollutants and moisture, regardless of the number of bedrooms.
Source: LEED Reference Guide for Homes Design and Construction, v4, Indoor Environmental Quality Prerequisite: Ventilation, p. 142.
The LEED v4.1 Residential BD+C rating system confirms:
EQ Prerequisite: Ventilation
Intermittent local exhaust in kitchens must provide at least 100 cfm (47 lps) per ASHRAE 62.2-2010 to ensure adequate ventilation in multi-family units, including two-bedroom units. Source: LEED v4.1 Residential BD+C, Credit Library, accessed via USGBC LEED Online. The correct answer is 100 cfm (47 lps) (Option A), as this is the minimum airflow requirement for intermittent kitchen exhaust per ASHRAE 62.2-2010.
Why not the other options?

B . 200 cfm (94 lps): This exceeds the minimum requirement for intermittent kitchen exhaust. C . 1 cfm per ft² (5.08 lps per m²): Kitchen exhaust is not based on floor area but on a fixed rate (100 cfm).
D . 2.5 cfm per ft² (12.7 lps per m²): This is also not based on floor area and is incorrect for kitchen exhaust.


Reference:

LEED Reference Guide for Homes Design and Construction, v4, EQ Prerequisite:
Ventilation, p. 142.
The LEED AP Homes Candidate Handbook emphasizes EQ prerequisites, including ventilation requirements, and references the LEED Reference Guide for Homes Design and Construction as a key resource. The exam is based on LEED v4, ensuring the relevance of ASHRAE 62.2-2010.

LEED Reference Guide for Homes Design and Construction, v4, USGBC, Indoor Environmental Quality Prerequisite: Ventilation, p. 142.
LEED v4.1 Residential BD+C, USGBC LEED Credit Library, accessed via LEED Online (https://www.usgbc.org/credits).
LEED AP Homes Candidate Handbook, GBCI, October 2024, p. 12 (references study resources and exam scope based on LEED v4).
USGBC LEED for Homes Rating System (v4), available via USGBC website (https://www.usgbc.org/resources/leed-homes-design-and-construction-v4). LEED v4.1 for Homes, USGBC, accessed via LEED Online, confirming kitchen exhaust requirements.



Viewing page 9 of 21
Viewing questions 41 - 45 out of 100 questions


Post your Comments and Discuss US Green Building Council LEED-AP-Homes exam prep with other Community members:

AI Tutor AI Tutor 👋 I’m here to help!