Free LEED-AP-O-M Exam Braindumps (page: 8)

Page 7 of 43

Which of the following topics is unnecessary in order to comply with the Sustainable Sites Credit, Site Improvement
Plan?

  1. Soils
  2. Hydrology
  3. Vegetation
  4. Maintenance equipment

Answer(s): D

Explanation:

The correct answer is D because maintenance equipment is not a topic that is required to be addressed in the Site Improvement Plan for the Sustainable Sites Credit, as stated in the LEED v4.1 O+M Reference Guide1. The Site Improvement Plan must include topics such as soils, hydrology, vegetation, and site management, and describe the existing conditions, goals, strategies, and performance metrics for each topic1. The other options are incorrect because they are topics that are required to be addressed in the Site Improvement Plan.


Reference:

LEED v4.1 O+M Reference Guide, page 115
Guide to the LEED AP Operations and Maintenance (O+M) Exam, page 80 LEED v4 AP O+M Mock Exam, page 86

In order to comply with the Sustainable Sites Credit, Site Improvement Plan, addressing the topics of soils, hydrology, and vegetation is essential. These elements are crucial for ensuring sustainable site management, enhancing site ecology, managing stormwater, and promoting biodiversity. However,

the topic of maintenance equipment, while important for operational considerations, is not directly necessary for compliance with this specific credit. The focus of the Site Improvement Plan is on the physical and ecological aspects of the site rather than the equipment used for site maintenance.

LEED v4 for Building Design and Construction Guide, U.S. Green Building Council.



What is the intent of Indoor Environmental Quality Credit, Daylight and Quality Views?

  1. To achieve a daylight factor in all spaces
  2. To provide lighting controls for regularly occupied spaces
  3. To achieve direct line of site to vision glazing for all building occupants
  4. To provide a connection between building occupants and the outdoor environment

Answer(s): D

Explanation:

The intent of Indoor Environmental Quality Credit, Daylight and Quality Views is D: to provide a connection between building occupants and the outdoor environment1. This credit aims to enhance the well-being, productivity, and satisfaction of building occupants by introducing natural light and views into the regularly occupied spaces2. The other options are incorrect because they either describe different aspects of the credit requirements or are not part of the credit intent.
1: Daylight and Views - Daylight - Chaney Enterprises 2: LEED v4.1 O+M Reference Guide, page 249

The intent of the Indoor Environmental Quality Credit, Daylight and Quality Views, is to provide a connection between building occupants and the outdoor environment. This credit emphasizes the importance of natural light and outside views in creating healthy and productive indoor spaces. By ensuring that interior spaces have access to daylight and views of the outdoors, buildings can enhance occupant well-being, reduce the need for artificial lighting, and promote a connection to the natural world. This credit encourages the design and orientation of buildings and interior spaces in a way that maximizes the penetration of natural light and provides clear lines of sight to outdoor environments.



Which of the following strategies is allowed under Energy and Atmosphere Credit, Renewable Energy and Carbon
Offsets, and will help a project achieve Energy and Atmosphere Credit, Optimize Energy Performance?

  1. Install an on-site photovoltaic array
  2. Purchase Green-e certified carbon offsets
  3. Purchase Green-e certified Renewable Energy Certificates (RECs)
  4. Install an on-site geothermal energy with a ground-source heat pump

Answer(s): A

Explanation:

The correct answer is A because installing an on-site photovoltaic array is a strategy that is allowed under Energy and Atmosphere Credit, Renewable Energy and Carbon Offsets, and will help a project achieve Energy and Atmosphere Credit, Optimize Energy Performance, as stated in the LEED v4.1 O+M Reference Guide1. An on-site photovoltaic array can generate renewable energy for the project and reduce its greenhouse gas emissions and energy costs1. The other options are incorrect because they either do not help the project achieve Energy and Atmosphere Credit, Optimize Energy Performance, or are not allowed by the credit requirements.


Reference:

LEED v4.1 O+M Reference Guide, page 145
Guide to the LEED AP Operations and Maintenance (O+M) Exam, page 90 LEED v4 AP O+M Mock Exam, page 87



What requirement must be met when creating a demand response program that satisfies Energy and Atmosphere Credit, Demand Response?

  1. Demonstrate a load shift reduction of 5% in the building
  2. Permanently reduce the energy consumption in the building by 5%
  3. Have the building management sign a two-year demand response enrollment
  4. Create a comprehensive plan for meeting the contractual commitment during a demand response event

Answer(s): D

Explanation:

The correct answer is D because creating a comprehensive plan for meeting the contractual commitment during a demand response event is a requirement for Energy and Atmosphere Credit, Demand Response, as stated in the LEED v4.1 O+M Reference Guide1. The plan must include the roles and responsibilities of the building staff, the communication protocols, the load reduction strategies, and the measurement and verification methods1. The other options are incorrect because they are either not required or relevant for this credit.


Reference:

LEED v4.1 O+M Reference Guide, page 151
Guide to the LEED AP Operations and Maintenance (O+M) Exam, page 91 LEED v4 AP O+M Mock Exam, page 88






Post your Comments and Discuss US Green Building Council LEED-AP-O-M exam with other Community members: