Free 3V0-41.19 Exam Braindumps (page: 4)

Page 3 of 13

An architect is helping an organization with the Physical Design of an NSX-T Data Center solution.
This information was gathered during a workshop:

- Some workloads should be moved to a Cloud Provider.
- Extend network's VLAN or VNI across sites on the same broadcast domain.
- Enable VM mobility use cases such as migration and disaster recovery without IP address changes.

- Support 1500 byte MTU between sites.
Which should the architect include in their design?

  1. SSL VPN
  2. Reflexive NAT
  3. L2 VPN
  4. Load Balancer

Answer(s): A



An architect is helping an organization with the Logical Design of an NSX-T Data Center solution. This information was gathered during the Assessment Phase:

- Customer Is concerned with NSX Manager availability.
- 3 cabinets/racks are available in the data center.
- No integration with 3rd party solution is required.
- There is no budget for physical equipment acquisition.
- The 3 cabinets/racks do not share the same L2 domain.
Which three should the architect include in their design to address the customer's concern with NSX Manager availability? (Choose three.)

  1. Use another NSX Manger IP in case an appliance falls.
  2. Deploy 2 cold standby NSX Manager appliances in rack 2/3.
  3. Deploy an NSX Manager Appliance per rack and cluster them.
  4. Use a physical/internal load-balancer with the cluster.
  5. Use separate IP per NSX Manager appliance per rack.
  6. Deploy a single active NSX Manager appliance in rack 1.

Answer(s): B,C,F



An architect is helping an organization with the Logical Design of an NSX-T Data Center solution. During discussions about Centralized Services NAT running on Tier-1 or Tier-0 LR the customer made these requests:
- Services contain stateful services.
- Services should be in high availability mode.
Which two should the architect include in their design? (Choose two.)

  1. An active/active model should be used.
  2. NAT should be applied on the uplink Interface.
  3. Mix stateful and stateless NAT rules on the same LR.
  4. The high availability mode supported is only Active-Stand by.
  5. Use only DNAT rules in stateful NAT.

Answer(s): A,D



An architect is helping an organization with the Physical Design of an NSX-T Data Center solution. This information was gathered during the Assessment Phase:

- Deployment will be a brownfield vSphere environment.

- A smooth transition for deployment is required.
Which two should the architect include in their design? (Choose two.)

  1. Separate management and NSX Edge clusters.
  2. Set an end-to-end MTU of 9000.
  3. The physical gateway will be migrated to the Tier-1 gateway.
  4. The ESXi hosts will need at least one free physical NIC.
  5. L2 connectivity will be the core convergent network.

Answer(s): B,C






Post your Comments and Discuss VMware 3V0-41.19 exam with other Community members:

3V0-41.19 Discussions & Posts