Which of the following ongoing procedures is required for water dispensers in Feature W06?
Answer(s): B
According to Feature W06 of WELL v2, water dispensers must be cleaned on a daily basis and their mouthpieces, outlets, protective guards, aerators, and basins must be maintained to ensure drinking water quality and hygiene.
Standard | WELL V2, Part 1: Ensure Drinking Water Access, Requirement 2: Dispenser maintenance Standard | WELL V2, Feature W06 Optimization Drinking Water Promotion, Summary
A consultant on a WELL project is working with the design team to enhance speech privacy in conference rooms.Which of the following would be most effective at maximizing speech privacy in these spaces?
Answer(s): D
According to Feature S06: Optimization Minimum Background Sound, part 1 of the WELL Core requirements, the project team must install a sound masking system in open areas and enclosed rooms designated as quiet zones, circulation zones and in areas where workstations are present1. The sound masking system produces a uniform artificial sound that increases speech privacy between occupied spaces by reducing the intelligibility of speech and masking unwanted noises2. The other options are not as effective at maximizing speech privacy in conference rooms, as they either do not address the sound transmission between rooms (A and C) or increase the noise level in the adjacent spaces (B).
= Standard | WELL V2, Daylight modeling | WELL Standard
Which strategy could a project pursue to meet requirements in a precondition in the Mind concept?
Answer(s): C
Mindfulness programming is a strategy that can help promote mental health and well-being by reducing stress, enhancing focus, and improving mood. Providing free mindfulness programming,such as yoga or meditation classes, is one of the possible ways to meet the requirements of the precondition M01: Mental Health Promotion in the Mind concept.
What's new in WELL v2: Mind | Articles | WELL International WELL Building Institute WELL Tip: Navigating preconditions for the Mind concept | Articles | WELL International WELL Building Institute
A project team performed quarterly water testing and determined that the total dissolved solids(TDS) is above the 500 mg/L threshold. Which of the following steps should the project team take to address this issue?
Answer(s): A
According to Feature W05: Optimization Drinking Water Quality Management, part 1 of the WELL Core requirements, the project team must test water quarterly in drinking water dispensers and meet the following thresholds: Total Dissolved Solids (TDS) are 500 mg/L or less. If any sample exceeds these thresholds, remediation and re-testing occur within a month1. Therefore, the project team should take the step of remediation and re-testing within one month to address the issue of high TDS levels.
= Standard | WELL V2
The WELL Building StandardTM (WELLTM) requires a project team to limit the use of pesticides to those with which Hazard Tier ranking?
Tier 3 pesticides are the least hazardous pesticides according to the City of San Francisco Pesticide Hazard Screening Protocol, which is one of the reference standards used by WELL v2 to evaluate pesticide safety. WELL v2 requires projects to use outdoor pesticides with a Hazard Tier ranking of 3,except in cases of emergency, and to implement an Integrated Pest Management plan to minimize pesticide use.
WELL v2 Feature X07 Optimization Pesticide Use, WELL v2 Feature X10 Optimization Pest Management and Pesticide Use