Free AD01 Exam Braindumps
Blue Prism Accredited Developer Questions 61–65 (page: 14)

Updated On: 10-Feb-2026

Which of the following Stages can be found Process Studio but NOT Object studio?

  1. Option A
  2. Option B
  3. Option C
  4. Option D

Answer(s): D



When mapping the Training application the User field has been spied, but on highlight the following situation is encountered:





Which of the following attributes would you use to help obtain a unique match?

  1. Ordinal
  2. parent Windows Text
  3. Height
  4. Control ID

Answer(s): A



Which of the following about an object's run mode is true?

  1. A run mode of background will enable the business object to run at the same time as other foreground business objects
  2. A run mode of background will enable the business object to run at the time a other background, foreground and exclusive business objects
  3. A run mode of exclusive cannot at the same time as any other business object
  4. The run mode of a business object has no influence on how many business objects can be run at the same time

Answer(s): C



How can an environment variable value be updated? (select all that apply)

  1. By using the Internal - Environment Variables business object
  2. By changing the Blue Prism Server configuration
  3. By updating the value in Control Room
  4. By updating the value in Credential Manager.
  5. By updating the value in System Manager

Answer(s): E



Consider the following process flow from the Main Page of a process in Process Studio:





Thinking about the standard Blue Prism Process Templates, what is wrong with this Main Page process flow?

  1. There is nothing wrong with the Main Page flow shown in the image, it is a copy of Blue Prism's standard Process Template
  2. The Stop? decision stage should be removed from the process flow, as Stop time is Configured either within the Scheduler process are stopped via Control Room.
  3. The Mam Page process flow is too high level For better visibility of the process logic the flow steps hidden m the sub-pages should al be on the main page instead.
  4. There is no exception handling on this Main Page so any exceptions that "bubble up" will cause the process to terminate rather than exceptions being handled correctly.
  5. The Reset Global Data page is not required because sub-page within a process should always use input parameter rather than global data items. There should be no global data to reset.

Answer(s): D



Viewing page 14 of 39
Viewing questions 66 - 70 out of 190 questions


Post your Comments and Discuss Blue Prism AD01 exam prep with other Community members:

AI Tutor AI Tutor 👋 I’m here to help!