Free AD01 Exam Braindumps
Blue Prism Accredited Developer Questions 71–75 (page: 16)

Updated On: 10-Feb-2026

Examine the following Blue Prism Action diagram taken from Object Studio:



What is wrong with the current configuration?

  1. The current configuration risks creating an infinite loop.
  2. The current configuration is missing an intelligent Wait stage after the 'Read Result Table' stage, to ensure the Action logic has worked correctly.
  3. There is nothing wrong with the current configuration.
  4. The Exception Block should be removed from the page so that all exceptions on that page can be recovered.

Answer(s): A



A Blue Prism solution works fine when developing and testing it in Process and Object Studio, but when it is run in Control Room, exceptions occur because elements are not being found.

What is the most likely cause of this behaviour?

  1. The target application has changed in design
  2. Intelligent Wait stages have not been used in line with Blue Prism best practices within Business Object Actions
  3. The Business Object Action has not been published, therefore, it cannot be used by a Process in Control Room.
  4. Exception handling best practice has not been incorporated into the Process design

Answer(s): B



Which of the statements below best describes what Blue Prism is used for?

  1. Blue Prism is used for modelling business processes
  2. Blue Prism is used to link core business applications together
  3. Blue Prism is used to create Virtual Digital Workers that can replicate user actions and decisions
  4. Blue Prism is used to transfer data from one system to another

Answer(s): C


Reference:

https://www.rpaforum.net/threads/which-of-these-phrases-best-describes-what-blue- prism-is-used-for.11153/



Examine the following Exception handling taken from the Main Page of a Blue Prism Process:



Consider the following potential explanations as to what is wrong with the design:

1. The exception handling is not within an Exception Block.

2. There is no Resume stage in the shown process flow.
3. There is a potential for the flow to cause an infinite loop within the process.
4. Because the flow is on the Main Page of the process there should not be a `Re-Throw' Exception stage as there are no parent/calling pages for the exception to `bubble up' to.

Which of the above appropriately describes what is wrong with this design?

  1. 1,2, 3 and 4
  2. 3 only
  3. 4 only
  4. 2 and 4

Answer(s): C



The staff number field of the Centrix Data Solutions business application can be spied successfully, however when using the Highlight feature in Application Modeller, the following behaviour is encountered:



Which of the following Attributes would you use to help obtain a unique element match?

  1. Parent Class Name
  2. Parent Ordinal
  3. Class Name
  4. Ordinal
  5. XandY

Answer(s): D



Viewing page 16 of 39
Viewing questions 76 - 80 out of 190 questions


Post your Comments and Discuss Blue Prism AD01 exam prep with other Community members:

AI Tutor AI Tutor 👋 I’m here to help!