What are the three parts of a Construction Specification Institute (CSI) specification?

  1. general, products, execution
  2. allowance, alternate, application
  3. information, purchasing, installing
  4. requirements, finishes, construction

Answer(s): A



A university is renovating the restrooms (washrooms) of a dormitory built in 1963 and is required to reduce the water usage by 20%.
What is MOST important when specifying plumbing fixtures?

  1. durability & Green Seal fixtures
  2. cleanability & Energy Star fixtures
  3. accessibility & WaterSense fixtures
  4. sustainability & International Plumbing Code compliant fixtures

Answer(s): C



What is the MAXIMUM occupant load of a business occupancy with one exit?

  1. 49
  2. 50
  3. 69
  4. 70

Answer(s): B



Which of the following factors in daylighting design determines the depth of light penetration into the space?

  1. window height
  2. shading device
  3. glazing material
  4. reflective surface

Answer(s): A



A client wants to remove the gypsum board from an existing structural column and leave it exposed.
What implications might this have on the fire rating of the assembly?

  1. Reduce the fire rating of the assembly
  2. Increase the fire rating of the assembly
  3. There would be no change in the fire rating of the assembly

Answer(s): A