Refer to the exhibit. The initiator that has FC ID 0x970102 fails to communicate with the target that has FC ID 0x970200. Which action resolves the issue?

  1. Reconfigure the initiator and the target to be in the same zones.
  2. Reactivate the zoneset.
  3. Reset the port for FC ID 0x970102 and FC ID 0x970200 to log in to the fabric.
  4. Reset the port for FC ID 0x970209 and FC ID 0x9700c2 to log in to the fabric.

Answer(s): B



A Cisco Nexus Series interface is errdisabled with the error message ‘DCX-No ACK in 100 PDUs†. What is thecause of this error?

  1. The host has not responded to the Control Sub-TLV DCBX exchanges of the switch.
  2. The acknowledgement number in the server response has not incremented for 100 exchanges.
  3. Cisco Discovery Protocol is disabled on the switch.
  4. LLDP is disabled on the switch.

Answer(s): B



A Fibre Channel interface on a Cisco Nexus 5000 Series Switch receives bit errors, and the switch disables the interface. A temporary workaround must be implemented before the root cause is identified. Which action prevents this issue from reoccurring?

  1. Verify that the SFPs are supported.
  2. Change the SFP to operate at 4 Gbps instead of 2 Gbps.
  3. Run the shutdown and then no shutdown commands on the interface.
  4. Run the switchportignore bit-errors command on the interface.

Answer(s): D



A fabric interconnect fails to start, and the console displays the loader prompt. Which two actions resolve the issue? (Choose two.)

  1. Load an uncorrupt bootloader image.
  2. Load an uncorrupt kickstart image.
  3. Reconnect Layer 1 and Layer 2 cables between the FIs.
  4. Reformat the fabric interconnect.
  5. Load the correct version of the boot image.

Answer(s): B,E



A Cisco UCS B-Series Blade Server is configured to boot a VMware ESXi host from an EMC VNX storage array by using a Fibre Channel SAN. The boot order is confirmed to be configured as expected, but the server fails to boot from the SAN. Which action resolves the problem?

  1. Set the boot LUN to the highest LUN ID in the storage array.
  2. Set the boot LUN to the lowest LUN ID in the storage array.
  3. Set the same WWNN pools for vHBA adapters.
  4. Set the same WWPN pools for vHBA adapters.

Answer(s): C