Refer to the exhibit. An engineer deploys a SAN environment with two interconnected Cisco MDS 9000 Series Switches. When the engineer attempts a zone merge, it fails with the error that is presented in the exhibit.


Which action resolves the issue?

  1. Import or export a zone set between the switches to synchronize the switches.
  2. Change the name of one of the zones to match the other zone set.
  3. Ensure that the zone members have different names.
  4. Set the distribute policy of the zone to full.

Answer(s): C


Reference:

https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5000/sw/troubleshooting/guide/N5K_Troubleshooting_Guide/n5K_ts_sans.html



An engineer must configure Linux hosts that are deployed on Cisco UCS B-Series Servers to boot from SAN. The SAN boot policy is configured in Cisco UCS Manager, and the boot order is verified to be set as expected. However, the Linux hosts fail to boot. Which action resolves the issue?

  1. Delete and reconfigure the boot LUN.
  2. Delete and reconfigure the pWWN of the SAN boot target.
  3. Remove all of the ISO images that are mounted as a virtual CD-ROM.
  4. Remove all of the local storage that is installed.

Answer(s): D


Reference:

https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/cli/config/guide/2-2/b_UCSM_CLI_Configuration_Guide_2_2/configuring_server_boot.pdf page 5



Refer to the exhibit. An engineer discovered a VFC interface in a down state on a Cisco Nexus Switch. Which action resolves the problem?

  1. Change the cable between the switch and the server
  2. Reset the Cisco Nexus port toward the file server
  3. Update the CNA firmware and driver versions
  4. Modify the fipkeepalive message time to 30 seconds

Answer(s): D


Reference:

https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5000/sw/troubleshooting/guide/N5K_Troubleshooting_Guide/n5K_ts_fcoe.html



Refer to the exhibit. A network engineer is configuring the FCoEN_Port virtualization storage area network. After the initial implementation, server 11 fails to connect to the disk array. Which action resolves the issue?

  1. On MDS interface vfc 1/1, change switchport mode configuration to VF
  2. On N9K interface vfc11, change switchport mode configuration to NP
  3. On N9K interface vfc11 and MDS interface vfc 1/1, change switchport mode configuration to F
  4. On N9K interface vfc11 and MDS interface vfc 1/1, change switchport mode configuration to E

Answer(s): D



Refer to the exhibits. An engineer is implementing the SAN based on the Cisco MDS 9000 Series Switches. When operating the environment, the engineer encounters the error shown. Which action resolves the issue?

  1. Copy VSAN 101 to the fabric binding database on the MDS-1 switch
  2. Add the World Wide Name of the neighboring switch to the MDS-1 switch
  3. Configure the port security feature on the MDS-1 switch
  4. Enable VSAN 101 on the peer MDS 2 switch fabric interconnect

Answer(s): B


Reference:

https://overlaid.net/2014/08/22/fc-security-for-ccie-dc-fabric-binding/