Free HPE0-S58 Exam Braindumps (page: 11)

Page 10 of 25

Refer to the exhibit.



A customer with the design shown needs to perform an in-place upgrade to its environment to scale the two- frame single homed Multimodule Link Aggregation Group (MLAG) configuration to a three-frame configuration. The new frame needs to provide a redundant 20Gb connection for the compute module ports in Fabric 3. Which interconnect modules should the integrator use in Frame 3?

  1. HPE Virtual Connect SE 40Gb F8 module in bay 3 and HPE Virtual Connect SE 40Gb F8 Module in bay 6
  2. HPE Synergy 10Gb Interconnect Link Module in bay 3 and HPE Synergy 10Gb Interconnect Link Module in bay 6
  3. HPE Synergy 20Gb Interconnect Link Module in bay 3 and HPE Synergy 20Gb Interconnect Link Module in bay 6
  4. HPE Synergy 20Gb Interconnect Link Module in bay 3 and HPE Synergy 10Gb Interconnect Link Module in bay 6

Answer(s): B



A customer is planning to deploy OneView for vCenter Server to improve management procedures for growing virtualization environment. The customer is concerned about resources required by HPE OneView for vCenter Server. Which statement about deploying HPE OneView for vCenter Server is true?

  1. It is deployed as an application on the Windows Server machine with at least 48GB of memory.
  2. It is deployed as a part of the HPE Composer installation.
  3. It is deployed as a virtual machine on the supported hypervisor.
  4. It can only be deployed if HPE Global Dashboard is already installed.

Answer(s): C


Reference:

https://support.hpe.com/hpsc/doc/public/display?docId=a00047122en_us



A customer has two Synergy frames using HPE Virtual Connect and 20Gb satellite modules linked together.
What is the maximum number of frames that can be added to this configuration? (Note: Enter your answer in the answer field below.)

  1. 3

Answer(s): A

Explanation:

3 (three) frames maximum



A customer wants to add nodes to the existing ESXi cluster using the HPE OneView for vCenter Server. What must be done before this functionality can be used?

  1. The cluster must be imported to HPE OneView
  2. An additional VMkernel port must be created for OneView integration
  3. All local datastores must be disconnected or removed from the other cluster nodes
  4. At least one node of the cluster must be placed in the maintenance mode

Answer(s): A


Reference:

https://support.hpe.com/hpsc/doc/public/display?docId=a00066686en_us