Free NS0-593 Exam Braindumps
NetApp Certified Support Engineer ONTAP Specialist Questions 16–20 (page: 5)

Updated On: 9-Feb-2026

You recently discovered the error message shown below in your ONTAP logs.



What should be your first action to correct this Issue?

  1. Power cycle all the disk storage shelves that contain drives of the aggregate with the my_data_vol volume.
  2. Determine the root cause behind the inconsistency before attempting any recovery procedure.
  3. Use the storage takeover command on the storage controller that contains my_data_vol.
  4. Use the wafliron command against my_data_vol to solve the inconsistency on the volume.

Answer(s): A



When an administrator tries to create a share for an existing volume named voll, the process fails with an error.

Referring to the exhibit, what Is the reason for the error?

  1. The volume must have a type of DP.
  2. The volume has not been mounted.
  3. The CIFS service is not authenticating properly with the domain controller.
  4. The CIFS service is not in workgroup mode.

Answer(s): B



The motherboard of Node-01 is being replaced. To perform this task, a takeover was Initiated from Node-02. Node-02 panics showing the string below.
PANIC; Permanent errors on all HA mailbox disks (while marshalling header) in SKprocess fnmbx_instanceWorker on release 9.5P8 (C)
What has happened in this situation?


  1. While in maintenance mode, the sldiag device show command was executed.

  2. While in maintenance mode, the fcadmin device_map command was executed.

  3. While in maintenance mode, the HA_config show command was executed.

  4. While in maintenance mode, the mailbox destroy local command was executed.

Answer(s): B



You are deploying NetApp ONTAP Select.
When trying to add VMware vCenter to the inventory, you receive the message shown below.
Credential authentication failed for x.x.x.x with: HostConnectionFailed In this scenario, how would you correct this problem?

  1. Change the vCenter password.
  2. Change the IP address of the ONTAP Select Deploy VM.
  3. Change the gateway address of the ONTAP Select Deploy VM.
  4. Change the IP address of the vCenter server.

Answer(s): A



You created a new NetApp ONTAP FlexGroup volume spanning six nodes and 12 aggregates with a total size of 4 TB. You added millions of files to the FlexGroup volume with a flat directory structure totaling 2 TB, and you receive an out of apace error message on your host.
What would cause this error?

  1. The maximum number of volume constituents has been reached in the ONTAP software.
  2. All constituent volumes are full.
  3. The inode limit is exceeded in the ONTAP software.
  4. The maxdirsize Is exceeded in the ONTAP software.

Answer(s): C