Refer to the exhibit. Software downgrade is required on a Cisco Nexus 7000 Series Switch. What is displayed when this command is executed?

  1. features that are enabled automatically after the downgrade
  2. impact of a software upgrade in ISSU and chassis reload
  3. features and commands that are removed automatically from the configuration
  4. compatibility of software in the system bootflash file

Answer(s): C

Explanation:


Reference:

https://www.cisco.com/c/en/us/td/docs/switches/datacenter/sw/best_practices/cli_mgmt_guide/cli_mgmt_bp/nxos_upgrade.html



The VMM domain is integrated between Cisco APICs and vCenter using a distributed vSwitch. The traffic must be blocked between a subset of endpoints in an
EPG based on specific VM attributes and the rest of the VMs in that EPG. Which set of actions blocks this traffic?

  1. 1. Set Allow Microsegmentation under the EPG VMM Domain Association to ג€Trueג€ 2. Set Intra-EPG Isolation to ג€Unenforcedג€ for the EPG 3. Set Intra-EPG Isolation to ג€Unenforcedג€ for the uSeg EPG
  2. 1. Set Allow Microsegmentation under the EPG VMM Domain Association to ג€Falseג€ 2. Set Intra-EPG Isolation to ג€Unenforcedג€ for the EPG 3. Set Intra-EPG Isolation to ג€Enforcedג€ for the uSeg EPG
  3. 1. Set Allow Microsegmentation under the EPG VMM Domain Association to ג€Trueג€ 2. Set Intra-EPG Isolation to ג€Enforcedג€ for the EPG 3. Set Intra-EPG Isolation to ג€Enforcedג€ for the uSeg EPG
  4. 1. Set Allow Microsegmentation under the EPG VMM Domain Association to ג€Trueג€ 2. Set Intra-EPG Isolation to ג€Enforcedג€ for the EPG 3. Set Intra-EPG Isolation to ג€Unenforcedג€ for the uSeg EPG

Answer(s): A

Explanation:


Reference:

https://www.cisco.com/c/en/us/solutions/collateral/data-center-virtualization/application-centric-infrastructure/white-paper-c11-743951.html



DRAG DROP (Drag and Drop is not supported)
Drag and drop the firmware packages from the left onto the software bundles they belong to on the right.
Select and Place:

  1. See Explanation section for answer.

Answer(s): A

Explanation:



Which action must be performed before renumbering a Cisco UCS chassis?

  1. Run the shut and no shut command on the connected ports.
  2. Move the chassis to new ports on fabric interconnect.
  3. Decommission the chassis.
  4. Re-acknowledge the chassis.

Answer(s): C

Explanation:

Decommissioning is performed when a chassis is physically present and connected but you want to temporarily remove it from the Cisco UCS Manager configuration. Because it is expected that a decommissioned chassis will be eventually recommissioned, a portion of the chassis' information is retained by Cisco
UCS Manager for future use.
Renumbering a Chassis -
Before You Begin -
If you are swapping IDs between chassis, you must first decommission both chassis, then wait for the chassis decommission FSM to complete before proceeding with the renumbering steps.


Reference:

https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/cli/config/guide/3-0/b_UCSM_CLI_User_Guide_3_0/ b_UCSM_CLI_User_Guide_3_0_chapter_0100011.pdf



Viewing page 23 of 132
Viewing questions 89 - 92 out of 549 questions



Post your Comments and Discuss Cisco® 350-601 exam prep with other Community members:

350-601 Exam Discussions & Posts